Introduction:
Rotary stick fatigue meter is mainly used for exercise coordination, balance testing, anti-fatigue drug screening and identification testing. Place the animal on a rotating rod in the center of the drum. To avoid slipping, the animal needs to adjust the balance and run with the rotating rod. The animal's time of persistence is used as an experimental index. If the animal is dropped, the instrument will automatically record the persistence time of the animal and the speed of the moment of falling.
In areas such as Parkinson's disease, alcohol dependence, Huntington's disease, mental development, dyskinesia, Alzheimer's disease, and drug evaluation, the animal's ability to move on a rod fatigue tester is considered to be a very important indicator; in addition, the instrument It can also be used to observe the relaxation effect of drugs on skeletal muscle and the inhibition of central nervous system, and determine whether the drug has bone relaxation effects by measuring the degree of reducing the coordinated movement of the rats on the rod. Technical features:
1.7 inch true color touch screen;
2. Speed range: 0.1~99.9 rev/min, adjustment: 0.1 rev/min;
3. With uniform acceleration function, acceleration can be adjusted, acceleration adjustment range: 0.1-50 rev / min;
4. Bottom charged stimulus (optional);
5. With statistical analysis function, real-time statistics of the average and standard deviation of each group of data;
6. Supports 6 mice or 3 rats for simultaneous testing;
7. The rod diameter of the rat was 90 mm, and the diameter of the mouse rod was 30 mm.
8. Experimental time setting range: 1~900 minutes;
9. Acceleration time setting range 1-4999 seconds;
10. Drop control: Photosensitive automatic recording;
11. Data display: real-time display in the stick time, number of rotations, speed;
12. Data records: Each channel is independently timed, individually detected and automatically ended;
13. Comes with a micro printer.
Introduction:
Rotary stick fatigue meter is mainly used for exercise coordination, balance testing, anti-fatigue drug screening and identification testing. Place the animal on a rotating rod in the center of the drum. To avoid slipping, the animal needs to adjust the balance and run with the rotating rod. The animal's time of persistence is used as an experimental index. If the animal is dropped, the instrument will automatically record the persistence time of the animal and the speed of the moment of falling.
In areas such as Parkinson's disease, alcohol dependence, Huntington's disease, mental development, dyskinesia, Alzheimer's disease, and drug evaluation, the animal's ability to move on a rod fatigue tester is considered to be a very important indicator; in addition, the instrument It can also be used to observe the relaxation effect of drugs on skeletal muscle and the inhibition of central nervous system, and determine whether the drug has bone relaxation effects by measuring the degree of reducing the coordinated movement of the rats on the rod.