    S180 cable identifier
    Introduction:
    The S180 Cable Identifier is designed for power cable engineers and cable workers to solve technical problems with cable identification. The user can accurately identify one of the target cables from multiple cables through the instrument, and avoid accidentally sawing the live cable and causing serious accidents. Cable identification starts from the operation of both ends of the cable. It must be ensured that the double number at both ends of the cable is accurate. The instrument is designed with PSK technology. No matter how reliable the memory of the field staff is, it is not a substitute for the identification of professional instruments. This product is only suitable for on-site identification of cables that have been powered off. It is strictly forbidden to connect this cable identifier to the running power cable! The instrument consists of a transmitter, a receiver, and a flexible current clamp.
    The transmitter adopts the pulse current principle to inject a pulse coded current signal into the cable core. The current generates an electromagnetic field around the target cable for detection, decoding and identification by the receiver and the flexible current clamp. Since the current is directional, the detection also has a direction. Sex. The transmitter adopts an integrated special toolbox design, using polypropylene plastic as raw material, adding a new composite filler into one injection molding, which has small density, strength, rigidity, hardness, wear resistance, heat resistance and insulation performance. The cabinet can withstand a pressure of about 200kg, and the host large LCD displays the remaining battery power in real time, and the white backlight and the dynamic signal of the transmitting signal are clear at a glance.
    The receiver is a handheld device, a 3.5-inch color LCD screen, and a built-in high-speed microprocessor that recognizes and decodes the pulsed current signal of the transmitter. The electronic dial indicates the signal strength, which is beautiful and intuitive; the color raster dynamic display makes it easy to automatically identify the target cable at a glance. At the same time, it has AC voltage detection function, and the range is AC 0.01V~600V (50Hz/60Hz).
    The flexible current clamp is a Rockwell coil with excellent transient tracking capability to quickly identify the pulsed current generated by the transmitter for thick cables or irregularly shaped conductors. The inner diameter of the jaw is about 200mm, and the cable with the clamp of Φ200mm or less can be clamped without disconnecting the measured line, and the non-contact measurement is safe and fast.
    Special note: This cable identifier is limited to cables with a target cable that is out of power. Please confirm that the target cable belongs to the range before use, that is, no live identification. When identifying, you need to use both the transmitter and the handheld receiver of the instrument.
    Technical Parameters:
    transmitter
    Function: Generate pulse coded current signal; display remaining battery voltage
    Power supply: 11.1V large capacity rechargeable lithium battery, fully charged for about 8 hours of continuous operation
    Display mode: Large LCD displays the remaining battery voltage in real time
    Pulse voltage: 500V
    Pulse current: up to 30A (depending on the loop resistance)
    Pulse frequency: 1 time / sec
    Pulse width: 2ms
    Transmit signal: Bar graph dynamically displays the transmitted signal
    Test line length: 3 meters, with alligator clips, 1 red and black
    Working temperature: -10 ° C ~ 40 ° C
    Total mass: 3.3 kg (with receiver)
    Outer package size: length, width, height, 400mm × 245mm × 335mm
    Battery power: When the battery voltage is lower than 9.65V, the battery voltage is low and the symbol is displayed to remind the battery to charge; when it is lower than 9.5V, the device automatically shuts down.
    Charger: 12.6V DC charger
    Receiver 
    Function: Cable identification (identification and decoding of pulse current signals); AC voltage measurement
    Power: 7.4V large capacity rechargeable lithium battery, USB charging interface, fully charged for about 8 hours of continuous operation
    Rated current: about 180mA max
    Display mode: 3.5 inch true color LCD display, color electronic dial indication
    Receiver size: length and width 207mm × 101mm × 45mm
    Flexible coil: length about 630mm, wire diameter 6 mm or 12.5mm
    Coil inner diameter: φ200mm
    Voltage range: AC 0.01V ~ 600V (50Hz / 60Hz)
    Voltage accuracy: ±1%±1dgt
    Battery voltage: When the battery voltage is lower than 6.5V, the battery voltage is low and the symbol is displayed to remind the battery to charge.
    Charger: 9V DC charger
    Working temperature and humidity: -10 ° C ~ 40 ° C; 80% Rh below
    Receiver quality: Receiver: 370g (with battery)
    Current clamp: 172g
    Insulation: ≥100MΩ between the instrument line and the sheathed casing
     
  • Introduction:
    The S180 Cable Identifier is designed for power cable engineers and cable workers to solve technical problems with cable identification. The user can accurately identify one of the target cables from multiple cables through the instrument, and avoid accidentally sawing the live cable and causing serious accidents. Cable identification starts from the operation of both ends of the cable. It must be ensured that the double number at both ends of the cable is accurate. The instrument is designed with PSK technology. No matter how reliable the memory of the field staff is, it is not a substitute for the identification of professional instruments. This product is only suitable for on-site identification of cables that have been powered off. It is strictly forbidden to connect this cable identifier to the running power cable! The instrument consists of a transmitter, a receiver, and a flexible current clamp.
    The transmitter adopts the pulse current principle to inject a pulse coded current signal into the cable core. The current generates an electromagnetic field around the target cable for detection, decoding and identification by the receiver and the flexible current clamp. Since the current is directional, the detection also has a direction. Sex. The transmitter adopts an integrated special toolbox design, using polypropylene plastic as raw material, adding a new composite filler into one injection molding, which has small density, strength, rigidity, hardness, wear resistance, heat resistance and insulation performance. The cabinet can withstand a pressure of about 200kg, and the host large LCD displays the remaining battery power in real time, and the white backlight and the dynamic signal of the transmitting signal are clear at a glance.
    The receiver is a handheld device, a 3.5-inch color LCD screen, and a built-in high-speed microprocessor that recognizes and decodes the pulsed current signal of the transmitter. The electronic dial indicates the signal strength, which is beautiful and intuitive; the color raster dynamic display makes it easy to automatically identify the target cable at a glance. At the same time, it has AC voltage detection function, and the range is AC 0.01V~600V (50Hz/60Hz).
    The flexible current clamp is a Rockwell coil with excellent transient tracking capability to quickly identify the pulsed current generated by the transmitter for thick cables or irregularly shaped conductors. The inner diameter of the jaw is about 200mm, and the cable with the clamp of Φ200mm or less can be clamped without disconnecting the measured line, and the non-contact measurement is safe and fast.
    Special note: This cable identifier is limited to cables with a target cable that is out of power. Please confirm that the target cable belongs to the range before use, that is, no live identification. When identifying, you need to use both the transmitter and the handheld receiver of the instrument.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com