RT100 transmittance and reflectance tester Introduction: The RT100 transmittance and reflectance meter supports transmittance and reflectance measurements, providing spectral curves that can be used to test the transmittance and reflectance of samples in the ultraviolet to near-infrared bands (up to 200-2500nm in width). Adopting an integrated design, the sample chamber can be completely closed, minimizing the influence of external light. The software is simple and easy to use, automatically determining whether the measurement results are qualified. RT100 is widely used in industries such as optical glass, thin films, displays, touch screens, and phone covers. Equipped with an integrating sphere, it can be used for testing the reflection and transmission spectra of samples with rough surfaces, such as spotlight glass, ground glass, etc. Features: 1. Flexible combination of transmission/reflection measurement schemes 2. Extremely wide spectral measurement range: 200nm-2500nm; 3. Simple, easy to operate, and easy to replace samples for testing 4. It can support measurement modes with and without an integrating sphere 5. Adopting high-precision spectral measurement technology, with high accuracy, fast measurement speed, and good stability; 6. It comes with calibration and calibration functions, making it convenient for users to calibrate and zero themselves; 7. The software can measure the entire spectral curve, automatically obtain the transmittance and reflectance values of 6 spectral positions, and set a threshold to automatically determine the results. Technical parameters: Power supply and plug: capable of continuous operation under 220V ± 10%, 50Hz power supply conditions. The plugs of instrument equipment should comply with Chinese national standards, otherwise suitable sockets for instrument plugs should be provided. Working environment: 10-35 ℃, relative humidity 10-80% (no condensation) Spectral range: 380-1050nm (up to 200-2500nm, customizable according to customer requirements). Sample stage size: 195 x 160 mm (W x D). Equipped with a closed sample compartment to reduce the impact of external light on measurement results. Light source: High performance halogen lamp (customizable according to spectral range and sample characteristics). RT100 software: can measure the entire spectral curve, automatically obtain the transmittance and reflectance values of 6 spectral positions, set thresholds to automatically determine whether the measurement is qualified or not.
Introduction: The RT100 transmittance and reflectance meter supports transmittance and reflectance measurements, providing spectral curves that can be used to test the transmittance and reflectance of samples in the ultraviolet to near-infrared bands (up to 200-2500nm in width). Adopting an integrated design, the sample chamber can be completely closed, minimizing the influence of external light. The software is simple and easy to use, automatically determining whether the measurement results are qualified. RT100 is widely used in industries such as optical glass, thin films, displays, touch screens, and phone covers. Equipped with an integrating sphere, it can be used for testing the reflection and transmission spectra of samples with rough surfaces, such as spotlight glass, ground glass, etc.