RST5200F electrochemical workstation Introduction: RST5200F electrochemical workstation. This workstation is an electrochemical analysis instrument and test instrument with completely independent intellectual property rights. RST5200F electrochemical workstation is a collection of electrochemical analysis methods in cyclic voltammetry, step voltammetry, pulse voltammetry, square wave voltammetry and other electrochemical analysis methods; it can also complete constant potential polarization, constant current polarization, potential, current, More than sixty electrochemical testing functions such as power step, Tafel diagram, AC impedance, etc. RST5200F electrochemical workstation is based on RST3100 electrochemical workstation to increase the AC impedance and other AC methods to increase the output current, increase the scanning speed, improve Potential and current resolution are added to the electrochemical test method by pulse electroplating method, battery charge and discharge and other AC test methods. RST5200F electrochemical workstation data acquisition and data processing software is based on Windows2000/XP and above operating system software. The user interface complies with the design rules of Windows software and is easy to install and use. The system software provides powerful functions for users, including file management, comprehensive experiment control, flexible graphic display, convenient graphic enlargement, reduction and restoration, bitmap graphic and data export, and multiple data processing functions. The system software has a good user interface, full Chinese menu, convenient peak identification and superposition, and it is more convenient for teaching and scientific research services. Main application areas: Electrochemistry Teaching Electrochemical analysis Electrochemical synthesis Trace element detection Electroplating process development Battery Material Research Environmental protection monitoring Nano-material development Electrolysis, metallurgy, pharmaceutical Bioelectrochemical sensor Electrochemical corrosion research and measurement Super capacitor characteristics test analysis Battery formation and characteristics test analysis Voltage and current time curve recorder Technical Parameters: Instrument architecture: potentiostat, galvanostat, AC impedance spectrometer, type F Groove pressure ±15V (expandable to ±22V or ±30V) Potential scan range: ±12.8V CV minimum potential increment: 0.0125mV Potential control accuracy: <±0.5mV Potential control noise: <0.01mV Potential rise time: <0.00025mS Potential measurement zero position: automatic correction Potential update and impedance acquisition rate: 10MHz Potential measurement low-pass filter: automatic or manual setting Potential measurement accuracy: 0.1% of full scale Scanning speed: 0.000001V/S~20000V/S Reference electrode input impedance//capacitance: >1013Ω// <10pF Maximum constant current output: ±0.5A continuous expander ±10A Input bias current: <0.1pA Current measurement resolution: 0.00076% of current range, minimum 0.2fA Current measurement zero position: automatic correction Current measurement range: 1pA~0.5A (total 25 files) Pre-magnification: 5×10×100 Maximum sensitivity of current measurement: 1×10-12A/V Current measurement accuracy: 0.1% of full scale Current measurement low-pass filter: automatic or manual setting Square wave voltammetry frequency 1Hz~100kHz AC voltammetry frequency 0.1Hz~10kHz SHACV frequency 0.1Hz~5KHz Frequency of AC impedance spectrum: 0.00001Hz~1MHz (11 frequency bands) Sine wave amplitude: 0.01mV~12V CA and CC pulse width 0.1mS~1200S DPV pulse width: 0.05mS~64S IR drop compensation: automatic or manual setting (10Ω~1MΩ) Multi-step cycle times: 1000 times Voltage limiting feedback constant current commutation time <0.1mS Constant current limit cycle 0.1S~100000S Instrument size: 36×30×14 (cubic centimeters) Instrument weight: 8kg
Introduction: RST5200F electrochemical workstation. This workstation is an electrochemical analysis instrument and test instrument with completely independent intellectual property rights. RST5200F electrochemical workstation is a collection of electrochemical analysis methods in cyclic voltammetry, step voltammetry, pulse voltammetry, square wave voltammetry and other electrochemical analysis methods; it can also complete constant potential polarization, constant current polarization, potential, current, More than sixty electrochemical testing functions such as power step, Tafel diagram, AC impedance, etc. RST5200F electrochemical workstation is based on RST3100 electrochemical workstation to increase the AC impedance and other AC methods to increase the output current, increase the scanning speed, improve Potential and current resolution are added to the electrochemical test method by pulse electroplating method, battery charge and discharge and other AC test methods. RST5200F electrochemical workstation data acquisition and data processing software is based on Windows2000/XP and above operating system software. The user interface complies with the design rules of Windows software and is easy to install and use. The system software provides powerful functions for users, including file management, comprehensive experiment control, flexible graphic display, convenient graphic enlargement, reduction and restoration, bitmap graphic and data export, and multiple data processing functions. The system software has a good user interface, full Chinese menu, convenient peak identification and superposition, and it is more convenient for teaching and scientific research services.