    RST5060F electrochemical workstation
     
    Introduction:
    This workstation is an electrochemical analysis instrument and test instrument with completely independent intellectual property rights. RST5200F electrochemical workstation is a collection of electrochemical analysis methods in cyclic voltammetry, step voltammetry, pulse voltammetry, square wave voltammetry and other electrochemical analysis methods; it can also complete constant potential polarization, constant current polarization, potential, current, More than sixty electrochemical testing functions such as power step, Tafel diagram, AC impedance, etc. RST5200F electrochemical workstation is based on RST3100 electrochemical workstation to increase the AC impedance and other AC methods to increase the output current, increase the scanning speed, improve Potential and current resolution are added to the electrochemical test method by pulse electroplating method, battery charge and discharge and other AC test methods. RST5200F electrochemical workstation data acquisition and data processing software is based on Windows2000/XP and above operating system software. The user interface complies with the design rules of Windows software and is easy to install and use. The system software provides powerful functions for users, including file management, comprehensive experiment control, flexible graphic display, convenient graphic enlargement, reduction and restoration, bitmap graphic and data export, and multiple data processing functions. The system software has a good user interface, full Chinese menu, convenient peak identification and superposition, and it is more convenient for teaching and scientific research services.
    Technical Parameters:
    Instrument architecture: potentiostat, potentiostat
    Grounding mode: can be set to solid mode or floating mode according to system requirements
    Groove pressure: ±15V
    Potential scan range: ±12.8V
    CV minimum potential increment: 0.0125mV
    Potential control accuracy: <±0.5mV
    Potential control noise: <0.01mV
    Potential rise time: <0.25uS
    Potential measurement zero position: automatic correction
    Potential update and impedance acquisition rate: 10MHz
    Potential measurement low-pass filter: automatic or manual setting
    Potential measurement accuracy: 0.1% of full scale
    Scanning speed: 0.000001V/S20000V/S
    Reference electrode input impedance // capacitance: >1013Ω//<10pF
    Maximum constant current output: ±500mA
    Input bias current: <0.1pA
    Current measurement resolution: 0.00076% of current range, minimum 0.2fA
    Current measurement zero position: automatic correction
    Current measurement range: 1pA500mA (25 files)
    Pre-magnification: 5×10×100
    Maximum sensitivity of current measurement: 1×10-12A/V
    Current measurement accuracy: 0.1% of full scale
    Current measurement low-pass filter: automatic or manual setting
    Square wave voltammetry frequency: 1Hz~100kHz
    CA and CC pulse width: 0.1mS1200S
    DPV pulse width: 0.05mS64S
    IR drop compensation: automatic or manual setting (10Ω~1MΩ)
    Multi-step cycle times: 1000 times
    Dual-channel high-speed ADC: 18bit@1Msps
    Maximum data length: 20,000,000 points
    Nitrogen stirring and knocking control output: two-way switch signal (+5V/10mA)
    Extended output: two photoelectric isolation digital signals
    Energy storage electrochemical measurement protection mode: polarity, voltage, current, time, link
    Electrode intelligent flexible protection: voltage overload, current overload
    Instrument size: 36*30*14 (cubic centimeters)
     
     
  • Introduction:
    This workstation is an electrochemical analysis instrument and test instrument with completely independent intellectual property rights. RST5200F electrochemical workstation is a collection of electrochemical analysis methods in cyclic voltammetry, step voltammetry, pulse voltammetry, square wave voltammetry and other electrochemical analysis methods; it can also complete constant potential polarization, constant current polarization, potential, current, More than sixty electrochemical testing functions such as power step, Tafel diagram, AC impedance, etc. RST5200F electrochemical workstation is based on RST3100 electrochemical workstation to increase the AC impedance and other AC methods to increase the output current, increase the scanning speed, improve Potential and current resolution are added to the electrochemical test method by pulse electroplating method, battery charge and discharge and other AC test methods. RST5200F electrochemical workstation data acquisition and data processing software is based on Windows2000/XP and above operating system software. The user interface complies with the design rules of Windows software and is easy to install and use. The system software provides powerful functions for users, including file management, comprehensive experiment control, flexible graphic display, convenient graphic enlargement, reduction and restoration, bitmap graphic and data export, and multiple data processing functions. The system software has a good user interface, full Chinese menu, convenient peak identification and superposition, and it is more convenient for teaching and scientific research services.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com