Introduction: This workstation is an electrochemical analysis instrument and test instrument with completely independent intellectual property rights. RST5200F electrochemical workstation is a collection of electrochemical analysis methods in cyclic voltammetry, step voltammetry, pulse voltammetry, square wave voltammetry and other electrochemical analysis methods; it can also complete constant potential polarization, constant current polarization, potential, current, More than sixty electrochemical testing functions such as power step, Tafel diagram, AC impedance, etc. RST5200F electrochemical workstation is based on RST3100 electrochemical workstation to increase the AC impedance and other AC methods to increase the output current, increase the scanning speed, improve Potential and current resolution are added to the electrochemical test method by pulse electroplating method, battery charge and discharge and other AC test methods. RST5200F electrochemical workstation data acquisition and data processing software is based on Windows2000/XP and above operating system software. The user interface complies with the design rules of Windows software and is easy to install and use. The system software provides powerful functions for users, including file management, comprehensive experiment control, flexible graphic display, convenient graphic enlargement, reduction and restoration, bitmap graphic and data export, and multiple data processing functions. The system software has a good user interface, full Chinese menu, convenient peak identification and superposition, and it is more convenient for teaching and scientific research services. Technical Parameters: Instrument architecture: potentiostat, potentiostat Grounding mode: can be set to solid mode or floating mode according to system requirements Groove pressure: ±15V Potential scan range: ±12.8V CV minimum potential increment: 0.0125mV Potential control accuracy: <±0.5mV Potential control noise: <0.01mV Potential rise time: <0.25uS Potential measurement zero position: automatic correction Potential update and impedance acquisition rate: 10MHz Potential measurement low-pass filter: automatic or manual setting Potential measurement accuracy: 0.1% of full scale Scanning speed: 0.000001V/S~20000V/S Reference electrode input impedance // capacitance: >1013Ω//<10pF Maximum constant current output: ±500mA Input bias current: <0.1pA Current measurement resolution: 0.00076% of current range, minimum 0.2fA Current measurement zero position: automatic correction Current measurement range: 1pA~500mA (25 files) Pre-magnification: 5×10×100 Maximum sensitivity of current measurement: 1×10-12A/V Current measurement accuracy: 0.1% of full scale Current measurement low-pass filter: automatic or manual setting Square wave voltammetry frequency: 1Hz~100kHz CA and CC pulse width: 0.1mS~1200S DPV pulse width: 0.05mS~64S IR drop compensation: automatic or manual setting (10Ω~1MΩ) Multi-step cycle times: 1000 times Dual-channel high-speed ADC: 18bit@1Msps Maximum data length: 20,000,000 points Nitrogen stirring and knocking control output: two-way switch signal (+5V/10mA) Extended output: two photoelectric isolation digital signals Energy storage electrochemical measurement protection mode: polarity, voltage, current, time, link Electrode intelligent flexible protection: voltage overload, current overload Instrument size: 36*30*14 (cubic centimeters)
Introduction: This workstation is an electrochemical analysis instrument and test instrument with completely independent intellectual property rights. RST5200F electrochemical workstation is a collection of electrochemical analysis methods in cyclic voltammetry, step voltammetry, pulse voltammetry, square wave voltammetry and other electrochemical analysis methods; it can also complete constant potential polarization, constant current polarization, potential, current, More than sixty electrochemical testing functions such as power step, Tafel diagram, AC impedance, etc. RST5200F electrochemical workstation is based on RST3100 electrochemical workstation to increase the AC impedance and other AC methods to increase the output current, increase the scanning speed, improve Potential and current resolution are added to the electrochemical test method by pulse electroplating method, battery charge and discharge and other AC test methods. RST5200F electrochemical workstation data acquisition and data processing software is based on Windows2000/XP and above operating system software. The user interface complies with the design rules of Windows software and is easy to install and use. The system software provides powerful functions for users, including file management, comprehensive experiment control, flexible graphic display, convenient graphic enlargement, reduction and restoration, bitmap graphic and data export, and multiple data processing functions. The system software has a good user interface, full Chinese menu, convenient peak identification and superposition, and it is more convenient for teaching and scientific research services.