Introduction: The AUTO-96 automatic PCR amplification instrument can be connected to the computer through the USB port or RS232/RS485 port. All operations are completed on the special software for the computer control of the PCR instrument. After the running file is issued, the machine can work without the computer to ensure that the experiment is not Affected by computer conditions; fast heating and cooling rate, the maximum heating and cooling rate is 5℃/s; small size, can be equipped with desktop pipetting workstation. Features: 1). Imported customized long-life Peltier module is adopted, and the number of cycles is more than 1 million; 2). The engineering reinforced aluminum module processed by anodizing technology not only retains fast thermal conductivity, but also has sufficient corrosion resistance; 3). Fast heating and cooling rate, the fastest heating and cooling rate is 5℃/s, saving valuable experiment time; 4). Electric self-adaptive hot cover, which can be adapted to 96-well PCR plates with full skirt and half skirt; 5). Small size, can be equipped with desktop pipetting workstation; 6). Connect to the computer through the USB port or RS232/RS485 port, all operations are completed on the special software for the computer control of the PCR instrument; 7). It can be run offline. When the computer crashes or the communication is interrupted, the work of the machine will not be affected, and the experiment can be carried out normally; 8). Automatic power-off protection, automatically execute the incomplete cycle after power supply is restored, to ensure the safe operation of the entire amplification process; 9). Support opening and adding samples during the experiment to meet various experimental needs; 10). The control software can be upgraded through the computer without other tools. Technical Parameters: Model: AUTO-96 Sample size: 96×0.2ml Test tube: 0.2ml single tube, 8-strip tube, 96-well skirted plate, 96-well semi-skirt plate, 96-well non-skirt plate Temperature range: 0-100℃ Maximum heating rate: 5℃/s Maximum cooling rate: 4℃/s Temperature uniformity: ≤±0.3℃ Temperature accuracy: ≤±0.2℃ Temperature display resolution: 0.1℃ Temperature control method: BlockTube Adjustable temperature change rate: 0.1-5℃/s Gradient temperature range: 30-100℃ Gradient setting range: 1-30℃ Temperature range of hot lid: 30-110℃ Heating lid height adjustment: electric heating lid Maximum steps of the program: 30 Maximum number of cycles of the program: 100 Time increment/decrement: 1 Sec-600 Sec Temperature increase/decrease: 0.1-10.0℃ Program pause function: Yes Power-down data protection: Yes 4℃ heat preservation: unlimited length Communication interface: USB2.0, RS232/RS485 Host size: 305mm×155mm×170mm (length×width×height) Product net weight: 14kg Input power: 100-240VAC, 50/60Hz, 600 W
Introduction: The AUTO-96 automatic PCR amplification instrument can be connected to the computer through the USB port or RS232/RS485 port. All operations are completed on the special software for the computer control of the PCR instrument. After the running file is issued, the machine can work without the computer to ensure that the experiment is not Affected by computer conditions; fast heating and cooling rate, the maximum heating and cooling rate is 5℃/s; small size, can be equipped with desktop pipetting workstation.