1 Sales RDM-1 wound radioactivity meter,Manufacturer

RDM-1 wound radioactivity meter

Product ID:CLQTfsjly012

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberRDM-1
    Brand NameSHRRFSFHSB
    Payment TermsT/T, paypal
    Brief introduction:
    Rdm-1 wound radiation meter USES sensitive semiconductor detector, with probe cover can be used for low level alpha radiation contamination detection on the surface of human wounds, but also can measure the dose rate of external radiation gamma after human wounds are contaminated by nuclides. It has good detection efficiency, high reliability and convenient operation characteristics. The instrument is controlled by a single chip microcomputer, which can continuously record and store the measurement data and obtain it by computer communication. The equipment can be used in many fields such as nuclear emergency response (as a complementary product of military nuclear emergency response box), nuclear medicine, nuclear power plants, nuclear fuel production, transportation, storage and commodity inspection. The control functions of the instrument include: background measurement timing selection, pollution measurement timing selection, alarm threshold setting, data communication selection, sound and light alarm, etc.
    Main technical indicators:
    1. Detector: semiconductor detector;
    2, Probe sensitive window area: J1-3.14cm2 and J2-19.6cm2 are optional (general sensitive area is Φ 20).
    3. Minimum distance from the edge of the probe port to the sensitive window: 4.5mm.
    4. Aluminum film mass thickness of probe window: < 1.1mg/ cm2.
    5. Instrument efficiency: η α 25% (239Puu, 4.5mm from window surface), η β 30%
    6. Instrument background: J1: α < 0.5cpmCmN J2: α < 1cpm,
    7. Counting range: counting rate 0.1 ~ 99999cpm;
    8.γ radiation measurement range: 0. 01 μ Sv/h~100mSv/h, relative error: ±15;
    9. Alarm settings: a: 1) 200cpm, continuously adjustable;
    10, built-in rechargeable lithium battery, a charge can last more than 7 days;
    11, the characteristics of environment: temperature from 20 to 50 , relative humidity RH 95% or less (@ 35 );
    12. Size/weight: host: 240 * 119 * 58;Probe: Φ 33 x 150;
    13. Total weight: 900g.

     
  • Brief introduction:
    Rdm-1 wound radiation meter USES sensitive semiconductor detector, with probe cover can be used for low level alpha radiation contamination detection on the surface of human wounds, but also can measure the dose rate of external radiation gamma after human wounds are contaminated by nuclides. It has good detection efficiency, high reliability and convenient operation characteristics. The instrument is controlled by a single chip microcomputer, which can continuously record and store the measurement data and obtain it by computer communication. The equipment can be used in many fields such as nuclear emergency response (as a complementary product of military nuclear emergency response box), nuclear medicine, nuclear power plants, nuclear fuel production, transportation, storage and commodity inspection. The control functions of the instrument include: background measurement timing selection, pollution measurement timing selection, alarm threshold setting, data communication selection, sound and light alarm, etc.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com