Introduction: The reciprocating cartridge dissolution apparatus simulates gastrointestinal conditions through simple programming, and performs in vitro dissolution pH profile analysis with biologically relevant stirring speeds and retention times. Can be used for release rate testing of buoyants, microspheres and chewables. Test and transfer a variety of samples with one instrument, saving valuable bench space. Samples are automatically transferred from one medium to another without operator intervention. RCWF-1 complies with reciprocating cylinder dissolution apparatus, USP 3 and USP 7, and EP conformance specifications. Features: 1. Automatic program operation: The RCWF-1 can automatically transfer samples to another row of media, has an independent sealing cover that opens and closes automatically, and can run for long periods of time when unattended. 2. Run flexible programming RCWF-1 can be freely programmed to directly control infiltration time, stroke length, stirring speed, reciprocation time, discharge time, sampling frequency, movement between the rows of dissolution vessels, etc. Single-row or double-row tests can be performed. Open procedures are more conducive to drug research and development. 3. Double row sample position RCWF-1 has a double row of sample positions, which can test 14 cups of samples at the same time, which is conducive to the comparison test of the original research product and the test product. 4. Flexible sampling point The RCWF-1 has a lifting section, which can locate the sampling needle position at full height. Technical parameter: Water bath temperature: 25~45℃ Temperature Resolution: 0.1℃ Temperature control error: ≤±0.2 Reciprocating stroke: USP3: 10±0.1cm USP7: 2cm Reciprocating times: 5~40 times/min Error: ±5% Sample position: 300ml specification, 8 rows of 14 cups (double row sample position), single and double row sample positions are adjustable Ambient temperature: 5~40℃ Relative humidity: ≤80% Working noise: ≤60dB Running time: adjustable Immersion time: adjustable Drain time: adjustable Heater: 1500W Power supply: 220V, 50Hz, 10A Safety performance: in line with national industry standards, with self-test and automatic protection functions
Introduction: The reciprocating cartridge dissolution apparatus simulates gastrointestinal conditions through simple programming, and performs in vitro dissolution pH profile analysis with biologically relevant stirring speeds and retention times. Can be used for release rate testing of buoyants, microspheres and chewables. Test and transfer a variety of samples with one instrument, saving valuable bench space. Samples are automatically transferred from one medium to another without operator intervention. RCWF-1 complies with reciprocating cylinder dissolution apparatus, USP 3 and USP 7, and EP conformance specifications.