PW series washing machine Introduction
Microcomputer control completes the cleaning of 48-well and 96-well microplates in various enzyme-free, time-resolved, and chemiluminescent laboratories. Widely used in hospital diagnostic laboratories, disease prevention and control institutions, inspection and quarantine institutions, animal husbandry and veterinary disease systems, biotechnology research units, food processing, environmental science, agricultural research and other units. Features
1. Wash 96 holes at the same time and wash two plates in one minute.
2, the double-plate tray can be placed at the same time with two enzyme-labeled plates, which can be cleaned by single board or alternately with double or multiple boards.
3, there is a blocking hole inspection program, which can easily eliminate the hidden danger of blocking holes and ensure the effectiveness of washing
4. Automatic extraction of the overflow and leakage in the enzyme label tray to ensure that the bottom of the enzyme label is not contaminated
5. The washing liquid bottle has a uniform volume calibration line, which is convenient for the preparation of the washing liquid, and the waste liquid is fully alarmed.
6, the cleaning head position adjustment six kinds (horizontal, left, middle, right, bottom, plate distance), the enzyme plate shape parameters are digitally displayed to 0.1mm, suitable for various sizes of different sizes of domestic and foreign ELISA plates
7, with a pause function, press the pause button to continue to complete the subsequent washing process
8. The number of holes in each strip on the microplate is not enough to fill the hole; has a transparent bio-cover to avoid laboratory bio-contamination during washing Technical Parameters
Pw960 technical parameters
1. Washing head structure design: 96 injection needles can be controlled, 8 controls and 12 controls can be converted in the same machine (ie 8-hole strip and 12-hole strip can be replaced by changing the cleaning head), 96 aspirating needles Synchronous control
2, with two points positioning liquid absorption function, the residual amount of each hole <1μl, to ensure clean and thorough;
3, secondary liquid splitting technology to ensure the amount of liquid added between 96 holes CV <1.5%
4, cleaning times: 1-99 times adjustable
5, the number of cleaning: the whole board or 1-12 can be arbitrarily combined, keyboard selection control and indication
6. Cleaning method: single board, double board or multiple boards
7, the amount of cleaning solution: 50-950μl / hole adjustable, 50μl interval
8, the washing speed is: 5 seconds / board / time
9, washing plate: A, B two
10, soaking or vibrating plate time: 0-999 seconds adjustable
11, the aspiration time is adjustable from 0.1 to 9.9 seconds, with an interval of 0.1 seconds
12. Each plate washing program and coating program independently store an enzyme plate shape size parameter
13, programmable 100 washing procedures and automatic storage, each washing program can edit the name of the experimental project
Pw812 technical parameters
1. Applicable to various types of enzyme standard plates Flat bottom plate, V-shaped bottom plate, U-shaped bottom plate, round bottom plate (both 96 holes and 48 holes)?
2. Average residual amount of cleaning solution: <0.7ul/hole
3, injection accuracy: 96-hole liquid addition error CV less than 1.5%?
4, cleaning head 8 channels and 12 channels?
5, the number of cleaning 1 ~ 999 times adjustable?
6, the number of cleaning 1 to 12 rows optional, quickly selected and indicated through the keyboard?
7, cleaning method Plate or strip?
8, the amount of cleaning solution added 50 ~ 950μl / per hole, interval 50μl adjustable (can be extended to 0 ~ 6000ul / hole, interval 25ul adjustable)
9. Infusion channel: 3 (2 kinds of washing liquid and 1 kind of distilled water, can be expanded to 5 kinds)
10, washing mode: 3 kinds, soaking, shock plate and shock bubble
11, mode time: 0 - 999 seconds / minute / hour adjustable
12, aspiration time: 0.1 - 99.9 seconds adjustable, 0.1 second interval
13, flushing pipeline time: 0 - 240 seconds adjustable
14, distilled water automatic flushing interval: 0 - 20 seconds plate
15, cleaning needle position parameters: five (horizontal, left, center, right, bottom) adjustable
Introduction
Microcomputer control completes the cleaning of 48-well and 96-well microplates in various enzyme-free, time-resolved, and chemiluminescent laboratories. Widely used in hospital diagnostic laboratories, disease prevention and control institutions, inspection and quarantine institutions, animal husbandry and veterinary disease systems, biotechnology research units, food processing, environmental science, agricultural research and other units.