1 Sales PLD-CGA1000 Composite Gas Analyzer,Manufacturer

PLD-CGA1000 Composite Gas Analyzer

Product ID:GSYqt026

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberPLD-CGA1000
    Brand NameBJBOFEILAI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    PLD-CGA1000 Composite Gas Analyzer
    Introduction:
    The PLD-CGA1000 composite gas analyzer can be used for rapid analysis of composite gas samples - hydrogen, oxygen, and nitrogen gases, with a total analysis time of less than 2.5 minutes for hydrogen and oxygen; There are two injection methods available: manual injection and online valve cut injection.
    Can be used as: hydrogen, oxygen, nitrogen rapid analysis equipment, recommended for MCP-WS1000 photochemical workstation analysis equipment; Can be used in conjunction with our other online detection equipment for rapid analysis of hydrogen, oxygen, and nitrogen online
    characteristic:
    1. Modular design can be used for rapid analysis of composite gas samples - hydrogen, oxygen, and nitrogen gases, with a total analysis time of less than 2.5 minutes for hydrogen and oxygen;
    2. Based on micro single gas path analysis technology, imported microelectromechanical (MEMS) sensors are used, with small dead volume, low gas consumption, high sensitivity, and a carrier gas flow rate of about 5 mL/min;
    3. It has two injection methods: manual injection and online valve cut injection;
    4. Mini portable design reduces usage space.
    Technical parameters:
    Working temperature control: 50 -80 constant, (adjustable, minimum increment 1 )
    Temperature stability: not greater than 0.3%
    Heating rate: 0.1C/mi-30C/min
    Sensitivity: 3000mV ▪ Ml/mg (benzene toluene)
    Noise: not greater than 0.3mV
    Drift: not greater than 3mV/30min:
    Temperature control accuracy: not greater than 0.3%
    Environmental temperature: 5-35
    Relative humidity: not exceeding 85%
    Minimum detectable amount of H2: 20ppm
    Power supply voltage: 220V ± 22V
    Minimum detection limit for O2: 200ppm
    Power supply frequency: 50Hz+1Hz
    Minimum detection limit for N2: 300ppm
    Maximum power consumption: 110W
    Repeatability: RSD1%
    Separation degree: 12
    Dimensions: 310x150x250 (mm) (length x width x height):
    Instrument weight: 4kg

  • Introduction:
    The PLD-CGA1000 composite gas analyzer can be used for rapid analysis of composite gas samples - hydrogen, oxygen, and nitrogen gases, with a total analysis time of less than 2.5 minutes for hydrogen and oxygen; There are two injection methods available: manual injection and online valve cut injection.
    Can be used as: hydrogen, oxygen, nitrogen rapid analysis equipment, recommended for MCP-WS1000 photochemical workstation analysis equipment; Can be used in conjunction with our other online detection equipment for rapid analysis of hydrogen, oxygen, and nitrogen online
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com