PLD-CGA1000 Composite Gas Analyzer Introduction: The PLD-CGA1000 composite gas analyzer can be used for rapid analysis of composite gas samples - hydrogen, oxygen, and nitrogen gases, with a total analysis time of less than 2.5 minutes for hydrogen and oxygen; There are two injection methods available: manual injection and online valve cut injection. Can be used as: hydrogen, oxygen, nitrogen rapid analysis equipment, recommended for MCP-WS1000 photochemical workstation analysis equipment; Can be used in conjunction with our other online detection equipment for rapid analysis of hydrogen, oxygen, and nitrogen online characteristic: 1. Modular design can be used for rapid analysis of composite gas samples - hydrogen, oxygen, and nitrogen gases, with a total analysis time of less than 2.5 minutes for hydrogen and oxygen; 2. Based on micro single gas path analysis technology, imported microelectromechanical (MEMS) sensors are used, with small dead volume, low gas consumption, high sensitivity, and a carrier gas flow rate of about 5 mL/min; 3. It has two injection methods: manual injection and online valve cut injection; 4. Mini portable design reduces usage space. Technical parameters: Working temperature control: 50 ℃ -80 ℃ constant, (adjustable, minimum increment 1 ℃) Temperature stability: not greater than 0.3% Heating rate: 0.1C/mi-30C/min Sensitivity: 3000mV ▪ Ml/mg (benzene toluene) Noise: not greater than 0.3mV Drift: not greater than 3mV/30min: Temperature control accuracy: not greater than 0.3% Environmental temperature: 5-35 ℃ Relative humidity: not exceeding 85% Minimum detectable amount of H2: 20ppm Power supply voltage: 220V ± 22V Minimum detection limit for O2: 200ppm Power supply frequency: 50Hz+1Hz Minimum detection limit for N2: 300ppm Maximum power consumption: 110W Repeatability: RSD1% Separation degree: 12 Dimensions: 310x150x250 (mm) (length x width x height): Instrument weight: 4kg
Introduction: The PLD-CGA1000 composite gas analyzer can be used for rapid analysis of composite gas samples - hydrogen, oxygen, and nitrogen gases, with a total analysis time of less than 2.5 minutes for hydrogen and oxygen; There are two injection methods available: manual injection and online valve cut injection. Can be used as: hydrogen, oxygen, nitrogen rapid analysis equipment, recommended for MCP-WS1000 photochemical workstation analysis equipment; Can be used in conjunction with our other online detection equipment for rapid analysis of hydrogen, oxygen, and nitrogen online