PHECDA-HE High Sensitivity XRF Heavy Metal Analyzer Features
Monochromatic aggregation excitation technology
The high-sensitivity XRF heavy metal analyzer uses a hyperboloid curved monochromator to optimize the excitation efficiency of the element and reduce the background of the continuous scattering lines of the X-ray tube to improve the signal-to-noise ratio of the element's fluorescent rays.
2. Using the highest performance SDD detector
The silicon drift detector (SDD) is the core component of the energy dispersive X-ray fluorescence spectrometer. Its performance depends on the crystal area, maximum counting rate, resolution, etc. The PHECDA series uses today's highest performance SDD detector to ensure elemental analysis performance.
3. Fast FP algorithm
The difficulty of XRF analysis is that the intensity of elemental fluorescence is not only related to the content of elements in the sample, but also to the content of other elements. This is the so-called matrix absorption-enhancement effect, and this physical effect makes it difficult to choose a suitable standard sample. The matrix of the selected standard sample is inconsistent and cannot cover the content range of each element of the sample to be tested, which will cause errors to the actual sample analysis.
Fundamental parameters method calculates the X-ray fluorescence spectrum from generation to detection and establishes corresponding mathematical models. The basic parameter method eliminates background differences caused by different types of sample substrates and reduces analysis errors. Elemental quantitative analysis results can be obtained by calibrating a few standards.
4. Optimize the detection capability of cadmium
Cadmium is a toxic heavy metal, and it has attracted much attention in the fields of environmental protection and food safety. Conventional XRF has challenges in the excitation and detection of cadmium (Kα: 23.1KeV). The detection limit for cadmium reaches an unprecedented level of 0.05 mg / kg.
5. Portability
Machine weight 8.5kg
No need for auxiliary equipment such as gas and vacuum
Maximum guarantee of on-site testing requirements Technical Parameters
index parameter
Principle Single-wavelength excitation-energy dispersive X-ray fluorescence spectrometry
Element range Mg-U
Detection limit (mg / kg) Cd: 0.05mg / kg
Pb: 0.1mg / kg
Cr: 0.3mg / kg
Repeatability Cd: 0.3mg / kg RSD < 15%
Sample type Solid sample, liquid sample, powder sample, viscous sample
Auto-injection Equipped with 30-bit auto-injection unit, can scan barcode
Software Fast FP software system, supporting various sample application development, spectrum display comparison, standardless quantification, standard sample calibration, element quantitative analysis, data storage, network transmission
Enrichment technology Combined technology of heavy metal enrichment diaphragm (HMET®) and HS XRF, the detection limit of heavy metals reaches 1 ~ 2ug / L
The PHECDA-HE high-sensitivity XRF heavy metal analyzer uses a hyperboloid curved monochromator to optimize the excitation efficiency of the element and reduce the background of the continuous scattering lines of the X-ray tube to improve the signal-to-noise ratio of the element's fluorescent rays. PHECDA-HE high-sensitivity XRF heavy metal analyzer is widely used in environmental monitoring, geology and geology, soil testing, university research and other fields.