PEC2000 Photoelectrochemical Test System Introduction: Photoelectrochemical experiments have strict requirements on the incident angle and energy of light. The PEC2000 photoelectrochemical test system adopts a more accurate multi-position intelligent position adjustment device. The influence of human operation on the incident angle and energy of light can be largely eliminated. At the same time, a variety of reactor placement positions are designed to meet your different photochemical testing needs. Application fields: PEC photoelectrochemical special equipment; photoelectrochemical Faradaic efficiency special equipment (need to be used in conjunction with 6A system) Features: 1. The equipment is integrated intelligently, the space is more compact, and the operation is easier; 2. High precision, automation and digitization make the experimental data more accurate; 3. Laser optical path alignment and positioning system 4. Design of automatic turntable working position (collimation position, optical power measurement position, single-chamber reaction position, customized reactor reaction position, etc.) 5. In a smaller volume, it has more functions, and can measure I-V, I-t, electrochemical impedance spectroscopy, hydrogen and oxygen generation, etc. 6. Can be used with 6A system to test Faraday efficiency Technical parameter: Lamp power: 300 W Power adjustment range: 150 W~300 W Rectangular uniform light spot: 10×10 mm~50×50 mm (according to the shooting distance) Irradiation intensity: 3000 mW/cm² Spectral range: 350~800 nm With the filter, you can get: ultraviolet region, visible region, near-infrared region and monochromatic light Irradiation inhomogeneity: ≤3% Long-term instability: ≤2% Precision optical feedback (high stability output), digital current display Reactor volume: 180 mL, effective volume about 90 mL Spectral range: 0.2~11 μm Range: 0~20W Turntable Y-axis adjustment range: 0~10 mm Measurement accuracy: 1 mWz Chopper Control: PFS40A Shutter Actuator Chopping time range: 1 s~30 min Box X-axis adjustment range: 0~80 mm Turntable position: collimation position, optical power measurement position, single-chamber reaction position, custom reactor reaction position Y-axis adjustment range of turntable: 0~10 mm
Introduction: Photoelectrochemical experiments have strict requirements on the incident angle and energy of light. The PEC2000 photoelectrochemical test system adopts a more accurate multi-position intelligent position adjustment device. The influence of human operation on the incident angle and energy of light can be largely eliminated. At the same time, a variety of reactor placement positions are designed to meet your different photochemical testing needs. Application fields: PEC photoelectrochemical special equipment; photoelectrochemical Faradaic efficiency special equipment (need to be used in conjunction with 6A system)