Brief introduction Nano-100 micro spectrophotometer is my company after a long period of research and the launch of a full wavelength spectrophotometer trace to quickly measure nucleic acid, protein concentration , cell solution . The amount of each sample required for measurement can be only 0.5 to 2ul . Directly to the sample point on the model . Without cuvettes or capillaries and other accessories. After the measurement , the sample can be selected directly and then wipe or pipette sample recovery . All steps simple and fast , all in one . And have the following characteristics: 1. Only trace volume of sample , required to reduce sample consumption , and without dilution , from 0.5 to 2ul sample to complete the measurement .
2. The detection wavelength range : 200 ~ 850nm
3. fast detection speed , without preheating can be readily detected . Each sample was measured in a very short period of time the test is completed
4. Longer life of optical components , identification user usage, no operation within five minutes , it will automatically turn off the light source , in order to prolong life,
5. When the user presses the test button when automatically open , the whole process without user intervention , automatic identification equipment Technical Specifications 1. Sample volume requirements : 0.5 ~ 2μL
2. The optical path : 0.2mm ( high concentration measurement ), 1.0mm ( general concentration measurement )
3. Light source: Xenon flash
4. Detector : 3864 -element linear CCD array
5. Wavelength range : 200 ~ 850nm
6. Wavelength accuracy : 1nm
7. wavelength resolution : 3nm (FWHM at Hg 546nm)
8. Absorbance accuracy : 0.003 Abs
9. Absorbance Accuracy: 1% ( 0.76 absorbance at 350nm)
10. Absorbance Range : 0.02 to 75 ( equivalent to 10mm) 11. Test time : 5S
12. Instrument Dimensions : W200 x D262 x H154 (mm)
13. Instrument Weight : 2.5kg
14. The sample holder material : silica fiber and high rigid aluminum
15. Power Adapter : 12V DC
16. Power : 12 ~ 18W
17. Software platform : Windows XP, Windows 7
Brief introduction Nano-100 micro spectrophotometer is my company after a long period of research and the launch of a full wavelength spectrophotometer trace to quickly measure nucleic acid, protein concentration , cell solution . The amount of each sample required for measurement can be only 0.5 to 2ul . Directly to the sample point on the model . Without cuvettes or capillaries and other accessories. After the measurement , the sample can be selected directly and then wipe or pipette sample recovery . All steps simple and fast , all in one . And have the following characteristics: