Brief introduction: The paperless recorder is a kind of input signal that needs to be monitored on the industrial field, such as temperature signal of thermal resistance and thermocouple, flow signal of flowmeter, pressure signal of pressure transmitter and so on. Data processing is carried out by high-performance microprocessor. On the one hand, the data of these monitoring signals are displayed on the high resolution LCD screen in various forms, and on the other hand, the data of these monitoring signals are stored in the large-capacity memory chip inside the instrument for direct data and graphics query, browsing and printing on the instrument. Product features: Standard instrument size 160mm*80mm Monochrome LCD display, 320*200 resolution 4 universal signal input, mA, V, mV, TC, RTD, etc Supports thermocouple input cold end compensation High accuracy signal input One minute interval can record 180 days without loss of data for 10 years Channel high and low limit alarm, 4 relay contact output 1 channel 4-20ma current output, 1 channel 24VDC power distribution USB 2.0 port, support instrument data export Various data expression forms, number display, bar chart, curve Support channel accumulation, and support class, daily, monthly and annual reports Standard RS232C/RS485 communication interface, standard ModbusRTU protocol Configuration file backup export function Product parameters: Number of channels: 1-4 options Input signal: type II standard signal: 0-20ma, 0-5v, 0-10v, 0-10mv, 0-100mv Ⅲ type standard signal (4-20 mA, (1-5) V Thermocouples: S, R, B, K, N, E, J, T, F1, F2, wre5-26, wre3-25 Thermal resistance: Pt00, Cu50, Cu53, BA1, BA2 Analog signals: sine, cosine, square, triangle Special customization: vacuum, PT1000, frequency Power distribution output: 24V(standard) Analog output: 4-20ma (optional) Alarm output: up to 4 relay alarm output (optional) Accuracy: + / - 0.2% FS Input impedance: standard current signal input is 250Q. Other signal inputs are greater than 20MQ. Isolation: the isolation voltage between channels and ground is greater than 500VAC, full isolation type, and the isolation voltage between channels is greater than 250VAC. Alarm output: normally open contact of 250VAC, 3A relay Insulation strength: power to ground/enclosure insulation strength is greater than 1500VAC, leakage current is 10mA, 1 min WATCHDOG: integrated WATCHDOG chip to ensure the long-term safe and reliable operation of the host Real-time clock: hardware real-time clock, powered by lithium battery after power off, the maximum clock error + / - 1 min/month. Power loss protection: all data is stored in FLASH memory, without the need for backup batteries, to ensure that all historical data and configuration parameters are not lost due to power loss. Communication mode: rs-485 and rs-232c communication interfaces are provided for users to choose (but cannot be used at the same time, where rs-485 serial bus is isolated from the host) and can be connected to micro printers. Baud rate: 1200bps, 2400bps, 4800bps, 9600bps, 1200bps, 19200bps, 38400bps, 57600 BPS is optional. Sampling period: 1 second, that is, 1 second sampling of each channel once The recording interval is 1 second, 2 seconds, 5 seconds, 10 seconds, 30 seconds, 1 minute, 2 minutes, 5 minutes, 10 minutes and 30 minutes Store 32Mb of content Storage time: 3-10 years (the specific time is determined according to the record interval and number of channels) Power supply: data can be stored for 10 years without loss Display: 100-240v; 24 VDC plus or minus 10% Size: 3in 320*320 high resolution OLED LCD display Appearance size: 160mmx80mm, opening size: 156mmx76mm.
Brief introduction: The paperless recorder is a kind of input signal that needs to be monitored on the industrial field, such as temperature signal of thermal resistance and thermocouple, flow signal of flowmeter, pressure signal of pressure transmitter and so on. Data processing is carried out by high-performance microprocessor. On the one hand, the data of these monitoring signals are displayed on the high resolution LCD screen in various forms, and on the other hand, the data of these monitoring signals are stored in the large-capacity memory chip inside the instrument for direct data and graphics query, browsing and printing on the instrument.