MC-SCX300 Monochrome Xenon Light Source Introduction: The wavelength tunable xenon lamp light source realizes continuous tunable wavelength, and is used in many fields such as material characterization, photoelectric testing, electrochemical analysis, photocatalysis and IPCE testing. The light source adopts a highly integrated integrated design, and the control power supply, trigger device and light source are integrated in the same light box to avoid problems such as difficulty in triggering the split cable-connected light source and electromagnetic interference during triggering; the shell is made of alloy material CNC precision machining, the core The components adopt a new heat dissipation mode, the core ideal upper limit temperature does not exceed 50 ℃, and the 38 ℃ constant temperature design of the whole machine makes the light source run more stable and the light source has a longer life. Features: 1. The instrument is composed of multiple modules, which can be adjusted flexibly and easily upgraded 2. Stable high-power continuous light source to ensure measurement repeatability; patented spectroscopic system to ensure good wavelength accuracy and repeatability, eliminate the influence of multi-level spectrum, and reduce stray light 3. Unique slit design, automatic protection of the cutting edge, good width adjustment symmetry, and long life 4. The application software is powerful, easy to use, easy to process graphs and data 5. Fine selection of materials, standard craftsmanship, excellent production, with good performance indicators and batch consistency Technical Parameters: 1. Light source structure: integrated light source. Control mode: integrated design of digital circuit control, highly integrated optical path, good stability, the system is integrated on an optical flat panel, and the position of the optical components is relatively stable; 2. Optimize the light path, improve the monochromatic light output efficiency of the light source, and the upper limit light output can reach 60mw/cm2; 3. The output bandwidth is continuously adjustable, 0.1~30nm; 4. The software can realize arbitrary adjustment of wavelength and delay setting, USB2.0 computer interface; 5. Asymmetrical level Czerny-Turner optical path, anti-coma design, can improve the symmetry of the spectral line and increase the optical resolution, the second-order dispersion design, effectively suppress stray light; 6. Multiple gratings can be flexibly configured according to specific needs; RS232 and USB interfaces, through the computer control of grating conversion, filter replacement and wavelength scanning, to achieve automatic wide-spectrum testing; 7. Precision worm gear drive, high accuracy and repeatability, low noise and long service life; 8. Unique slit design, automatic protection of the cutting edge, width adjustment symmetry, good long service life; 9. Equipped with a dedicated port for nitrogen filling, which is convenient for use in the wavelength range of ultraviolet and near-infrared with atmospheric absorption spectrum, and it must be used in a nitrogen environment below 300nm; 10. The optical room and the mechanical transmission room are strictly separated to avoid the latter's stray light and the pollution of the optical parts caused by the trace of lubricating oil volatilization; 11. The monochromator body is an integral structure of castings to ensure the stability of the optical system. 12. Spectral range: 300-1600nm; 13. Output optical power density: 2mw/cm2-60mw/cm2 The output bandwidth is continuously adjustable, 0.1~30nm; Stability The stability of light output is better than 0.5%; Applied material characterization, photoelectric testing, electrochemical analysis, photocatalysis And IPCE test; 14. The light source adopts a highly integrated integrated design. The control power supply, trigger device and light source are partially integrated in the same light box to avoid problems such as difficulty in triggering the split cable-connected light source and electromagnetic interference during triggering.
Introduction: The wavelength tunable xenon lamp light source realizes continuous tunable wavelength, and is used in many fields such as material characterization, photoelectric testing, electrochemical analysis, photocatalysis and IPCE testing. The light source adopts a highly integrated integrated design, and the control power supply, trigger device and light source are integrated in the same light box to avoid problems such as difficulty in triggering the split cable-connected light source and electromagnetic interference during triggering; the shell is made of alloy material CNC precision machining, the core The components adopt a new heat dissipation mode, the core ideal upper limit temperature does not exceed 50 ℃, and the 38 ℃ constant temperature design of the whole machine makes the light source run more stable and the light source has a longer life.