Introduction: MA-6000 adopts high-quality Marlow semiconductor thermoelectric module, combined with German high-end PT1000 temperature sensor and electrical resistance heating compensation edge temperature control mode. The fluorescent signal in 96 sample holes is transmitted to Gaoxin through imported high-temperature professional optical fiber. The noise ratio is -20℃ cold low temperature CCD for real-time detection; it is an open design fully automatic fluorescent quantitative PCR instrument with completely independent intellectual property rights. The MA-6000 is equipped with a 5-color fluorescent channel detection platform as standard. The independent maintenance-free full-wavelength halogen tungsten lamp is used as the excitation light source. It is operated through the built-in computer touch screen or an external computer, which is efficient and portable. It can be widely used in basic medical research, pathogen detection, molecular cloning, genetic screening, gene expression, genotyping, genetic modification testing, food safety testing and public health epidemic monitoring and other industries and fields. Technical parameters: Sample capacity: 96x0.2ml, 12×8 tube strip Applicable consumables: 0.2ml single tube, 8x0.2ml row tube, 96-well plate (applicable to domestic tubes) Reaction system: 6ul-125ul, support fast reaction mode system Heating/cooling module: Semiconductor thermoelectric module Temperature control range: 4℃~100℃ Heating rate: 5℃/S (maximum) 3.5℃/S (average) Cooling speed: 5℃/S (maximum) 3.2℃/S (average) Temperature control accuracy: ±0.1℃ Number of temperature control zones: 6 zones of independent temperature control, combined with thermal compensation technology to reduce temperature edge effects Temperature uniformity: ±0.2℃ Gradient temperature change range: 1℃~32℃ Gradient temperature selection range: 30℃~100℃ (room temperature is lower than 28℃) Excitation light wavelength range: 380nm~780nm Number of excitation light channels: 5 (expandable to 6 channels) Detection component: -20℃ CCD Detection light wavelength range: 380nm~780nm Number of detection channels: 5 (expandable to 6 channels) Sensitivity: ≥1 copy Fluorescence intensity detection repeatability: CV≤3% Sample test repeatability: CV≤3% Linear range: 100-1010 Fluorescence and sample linear regression coefficient: r ≥0.980 Resolution: Single response as low as 1.5 times change Remote monitoring: can be networked with laboratory information management system Data output form: user setting Basic parameters of the instrument: Size: 600x390x320 (length x width x height: mm) power supply: 100~240V,
Introduction: MA-6000 adopts high-quality Marlow semiconductor thermoelectric module, combined with German high-end PT1000 temperature sensor and electrical resistance heating compensation edge temperature control mode. The fluorescent signal in 96 sample holes is transmitted to Gaoxin through imported high-temperature professional optical fiber. The noise ratio is -20℃ cold low temperature CCD for real-time detection; it is an open design fully automatic fluorescent quantitative PCR instrument with completely independent intellectual property rights. The MA-6000 is equipped with a 5-color fluorescent channel detection platform as standard. The independent maintenance-free full-wavelength halogen tungsten lamp is used as the excitation light source. It is operated through the built-in computer touch screen or an external computer, which is efficient and portable. It can be widely used in basic medical research, pathogen detection, molecular cloning, genetic screening, gene expression, genotyping, genetic modification testing, food safety testing and public health epidemic monitoring and other industries and fields.