MA-1B automatic fast Karl Fischer moisture analyzer for Solid moisture measurement

Product ID:FDks023

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberMA-1B
    Brand NameSHANGHAIBENANG
    Payment TermsT/T, paypal
    MA-1B automatic fast Karl Fischer moisture analyzer
     
    Introduction:
    MA-1B automatic fast Karl Fischer moisture analyzer uses the volumetric titration method with Karl Fischer reagent as the standard solution as the analysis principle, and has the end point indicator function. The MA-1B automatic fast Karl Fischer moisture analyzer has accurate terminal indication, convenient use, stable performance, and low price. It effectively replaces the traditional manual visual KF-1 and KF-1B moisture analyzers.
    Features:
    1. There are two operation methods for the measurement method: manual and automatic. The solenoid valve is used to adjust the measurement flow and automatically indicate the end point;
    2. After the start of the measurement, the instrument automatically adjusts the rapid titration according to the moisture content
    3. End point automatic locking device, with end point red light indication;
    4. Automatic waste discharge device, no need to manually discharge waste liquid, safe and convenient to use.
    MA-1B automatic fast Karl Fischer moisture analyzer host part: the ammeter clearly displays the titration process dynamically; the control panel is simple and clear design and can be operated immediately.
    Solenoid valve: It is made of imported materials, which eliminates the leakage of ordinary solenoid valves; it breaks through the manual titration of the traditional moisture analyzer and realizes automatic titration and automatic titration speed adjustment.
    Glass burette: It is made of German glass manufacturing process, which can clearly and intuitively see the titration process, and the titration accuracy is more accurate.
    Double platinum electrode: Since Karl Fischer reagent is a strong oxidizing and corrosive medium, general metals and plastics cannot be used, so the electrode of the Karl Fischer moisture analyzer is platinum, and the platinum electrode automatically judges and displays the end of the reaction.
    Reaction bottle: The glass material reaction bottle eliminates the problem of Karl Fischer reagent or the reaction between the sample and the reagent bottle, ensuring the accuracy of the test; at the same time, the reaction process can be clearly and intuitively seen. Once the operation is wrong, it can be interrupted immediately.
     Technical index
    1. Measuring range: 30×10-6100%, commonly used 0.0390%
    2. Relative standard deviation ≤ 2%
    3. Power supply voltage: AC 220 ± 22V
     
  • Introduction:
    MA-1B automatic fast Karl Fischer moisture analyzer uses the volumetric titration method with Karl Fischer reagent as the standard solution as the analysis principle, and has the end point indicator function. The MA-1B automatic fast Karl Fischer moisture analyzer has accurate terminal indication, convenient use, stable performance, and low price. It effectively replaces the traditional manual visual KF-1 and KF-1B moisture analyzers.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com