LY-DOAS Ultralow Concentration Ultraviolet Differential Gas Measurement

Product ID:HQZXyanqi045

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberLY-DOAS
    Brand NameQINGDAOLAOYING
    Payment TermsTT,PAYPAL
    LY-DOAS Ultralow Concentration Ultraviolet Differential Gas Measurement Optical Module
    Introduction:
    The ultra-low concentration ultraviolet differential gas measurement optical module uses ultraviolet differential absorption spectroscopy (DOAS) technology to simultaneously measure harmful gases such as SO2 and NOx. It has many advantages such as high measurement accuracy, fast measurement speed, simultaneous detection of multiple components, strong anti-interference ability, and low detection limit. It can be widely used in fields such as fixed pollution source exhaust gas analysis, mobile pollution source exhaust gas analysis, industrial process gas analysis, and laboratory gas analysis.
    characteristic:
    1. Using UV differential absorption spectroscopy to detect the concentration of gases such as SO2, NO, and NO2 in real-time, without interference from water vapor or dust
    2. Adopting self-developed deep UV spectrometer to optimize UV spectral response performance
    3. Adopting low-power pulse xenon lamp light source, low power consumption, long service life, and short preheating time
    4. The gas chamber adopts constant temperature control to ensure the accuracy and stability of the detection results
    5. Directly detect NO2 without the need for a conversion furnace
    6. Customizable range
    7. The mechanical structure can be customized according to needs
    Technical parameters:
    Measurement gas: SO2; NO NO2
    Range: 0-300mg/m3; 0-150mg/m3 0-200mg/m3 Customizable according to user needs
    Indication error: ≤ ± 2% FS
    Detection limit: ≤ 1mg/m3
    Repeatability: ≤ 1% FS
    Zero drift: ≤ ± 2% FS/24h
    Range drift: ≤ ± 2% FS/24h
    Calibration: Provide zero point calibration and range calibration
    Response time: T90 ≤ 30 s@1L /min
    Working temperature: (0-40)
    Relative humidity: ≤ 95% RH
    Output signal: concentration value/original AD value
    Communication interface: either RS232/RS485
    Power supply: DC12V/24V
    Power: less than 100W (during startup and preheating); Rated power less than 15W (during stable operation)
    Mechanical size: 300mm × 135mm × 115mm
    Weight:<1.6Kg


     
     
  • Introduction:
    The ultra-low concentration ultraviolet differential gas measurement optical module uses ultraviolet differential absorption spectroscopy (DOAS) technology to simultaneously measure harmful gases such as SO2 and NOx. It has many advantages such as high measurement accuracy, fast measurement speed, simultaneous detection of multiple components, strong anti-interference ability, and low detection limit. It can be widely used in fields such as fixed pollution source exhaust gas analysis, mobile pollution source exhaust gas analysis, industrial process gas analysis, and laboratory gas analysis.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com