Position: Home > > Environmental monitoring and analysis > Airborne particulate matter > Particle counter > LPC-5100 large flow laser dust particle counter

LPC-5100 large flow laser dust particle counter

Product ID:HQKLlzjs030

Price: Please inquire PDF Format
Supply Ability:60 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberLPC-5100
    Brand NameSUZHOUSHANGTIANJIEJING
    Payment TermsT/T, paypal
    LPC-5100 large flow laser dust particle counter
    Introduction
    The LPC-5100 high-flow laser dust particle counter is a successful product developed according to the requirements of the new GMP (2010 version). The overall body of the product is made of SUS 316L stainless steel. The laser sensor uses an all-semiconductor laser and a semiconductor photodiode receiver to ensure the stability of the light source and the accuracy of the signal receiver. The scattered light in the scattering cavity is greatly reduced, and the signal to noise ratio of the sensor is improved. With 8" color touch screen display and control, the display data is clear and easy to operate. The imported electronic flow sensor is used to ensure the accuracy of the sampling flow. The instrument can automatically judge various purification levels according to the criteria selected by the customer. Used in medical, pharmaceutical, electronic, chemical, optical, food, cosmetic, biological products, aerospace and various testing agencies for the detection of dust particles. 
    Technical parameters
    Model: LPC-5100
    Light source: semiconductor laser, life expectancy greater than 10 years >50000h
    Sampling flow: 100L/min (3.53CFM)
    Display mode: 8” color touch screen, Chinese and English interface selection, real-time display, previous cycle display, real-time density display, display time, date, measured value, temperature and humidity, room number, sampling point, sampling times, status, etc. 95% UCL calculation, directly showing particle concentration (particles/cubic meter)
    Measurement method: Single measurement / calculation measurement / confidence measurement
    Particle size channel: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0μm six-speed particle size display (optional 25μm)
    Sampling period: 1-99 minutes and 99 seconds optional; delay time: 0-99S; interval time: 0-999s; continuous sampling times: 0-99 times
    Self-cleaning time: ≤10 (min)
    UCL settings: The report complies with IS014644-1. GMP (2010) . 209E. YY0033-2000. GB50687-2011
    Data storage: ≥ 20000 sets of single measurement / 10000 sets of UCL
    Alarm function: After the standard of 100, 1000, 1000, 100000, 300000, 1000000 in the clean room exceeds the standard, and the A/B/C/D four levels of static and dynamic standards are met in accordance with the new GMP standard.
    Printer: Built-in thermal printer (print paper can be stored for 10 years)
    Power supply: Built-in 16.8V large capacity lithium battery, power adapter AC: 80-240V 50/60 Hz (use time is about 4h)
    Dimensions: 460 × 350 × 240 mm3 (W × D × H) about 11Kg
    Standard configuration: Equal power sampling head / sampling tube (1.8m) / sampling bracket / zero counting filter / power line / printing paper / standard packing box
    Data export: USB interface
    Other functions: 1. You can choose the print particle channel as needed.
    2. In various report standard modes, measured value, calculated value, UCL value and level judgment can be printed with one button.
    Optional function: 1. Automatic flow adjustment function (built-in gas flow quality controller)
    2. Temperature and humidity probe (measurement range: -40 to +123.8 °C 0 to 100% RH;
                 Accuracy: ±0.4°C ±3%RH)
    3-1. Three-level user password management (password can be set freely), use the instrument according to different operators' different permissions
    3-2. With audit trail function

  • Introduction
    The LPC-5100 high-flow laser dust particle counter is a successful product developed according to the requirements of the new GMP (2010 version). The overall body of the product is made of SUS 316L stainless steel. The laser sensor uses an all-semiconductor laser and a semiconductor photodiode receiver to ensure the stability of the light source and the accuracy of the signal receiver. The scattered light in the scattering cavity is greatly reduced, and the signal to noise ratio of the sensor is improved. With 8" color touch screen display and control, the display data is clear and easy to operate. The imported electronic flow sensor is used to ensure the accuracy of the sampling flow. The instrument can automatically judge various purification levels according to the criteria selected by the customer. Used in medical, pharmaceutical, electronic, chemical, optical, food, cosmetic, biological products, aerospace and various testing agencies for the detection of dust particles. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com