LK5100 Electrochemiluminescence Analysis system

Product ID:SHFZhxfa010

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberLK5100
    Brand NameTJLLK
    Payment TermsT/T, paypal
    Product description:
    The electrochemiluminescence analysis system of LK5100 integrates electrochemistry and luminescence analysis, which is convenient to use and easy to control accurately. It ensures that the determination results of electroluminescent analysis are more accurate and stable, and the sensitivity of the determination is greatly improved. Especially for the determination of trace substances, more advantages. Applications: detection and analysis of drugs, amino acids, peptides, proteins and nucleic acids, studies on interactions between proteins and drugs, nucleic acids, and determination of trace substances in the field of environmental ecology and food hygiene.
    Working environment:
    1) Environmental temperature: -15 ℃ ~ 45 ℃
    2) Environmental relative humidity: < 75%
    3) the air around the instrument is well ventilated and there is no corrosive gas in the air.
    4) there is no strong electromagnetic interference around the instrument.
    5) Power supply voltage: ac 220 V / C 50 Hz.
    Available test methods:
    Chemiluminescence analysis
    Electrochemiluminescence simultaneous detection: pulse potential electroluminescence analysis, single step chronoelectric current and electrochemiluminescence simultaneous detection, double potential-step chronoelectric current electrochemiluminescence simultaneous detection. Simultaneous detection of linear scanning voltammetry and electrochemiluminescence, cyclic voltammetry and electrochemiluminescence Electrochemical detection:
    Potentiostatic technique: open circuit potential-time measurement curve, single electric step over chronoelectric current method, double electric step over chronoelectric current method, single electric step over chronoelectric quantity method, double potential step over timing electric quantity method, constant potential electrolytic
    Coulomb analysis method;
    Linear scanning technique: linear scanning voltammetry, cyclic voltammetry, Tafel curve measurement, linear scanning stripping voltammetry;
    Pulse technique: differential pulse voltammetry, differential pulse stripping voltammetry; Square wave technique: square wave voltammetry, square wave stripping voltammetry.
    Technical parameters:
    Detector: Antimony cesium photocathode of photocathode
    Background noise: <10RLU (0. 1 seconds count time)
    Repetitive CV < 3%
    Stability CV less than 3%
    Linear range from 50 to 2 x 106RLU
    Correlation coefficient > 0.999
    Spectrum (response) range from 300nm to 650nm
    Scanning speed 0.01mV/s ~ 5000V/s
    Minimum resolution 0.01Mv
    Lower limit of current detection lower than 10pA
    Constant potential range - 10 ~ +10V
    Constant current range from -250 to +250mA
    The amplitude of square wave is 0.001 ~ 0.5V,
    Sampling interval from 0.0001 to 60000Sec
    Maximum output voltage -28V ~ +28V
    Frequency of communication from 0.0001 to 100KHz
    Potential range: -10V~10V;
    Sensitivity 1 x 10-14
    Current range: 250mA;
    The input impedance of the reference electrode: >1012 omega;
    Input bias current: <20pA;
    Potential increment: 0.01mV;
    The scanning rate: 0.00001 ~ 10000V/S;
    Current measurement resolution: <0.2pA;
     
  • Product description:
    The electrochemiluminescence analysis system of LK5100 integrates electrochemistry and luminescence analysis, which is convenient to use and easy to control accurately. It ensures that the determination results of electroluminescent analysis are more accurate and stable, and the sensitivity of the determination is greatly improved. Especially for the determination of trace substances, more advantages. Applications: detection and analysis of drugs, amino acids, peptides, proteins and nucleic acids, studies on interactions between proteins and drugs, nucleic acids, and determination of trace substances in the field of environmental ecology and food hygiene.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com