Introduction: LIFS-405 series laser-induced fluorescence spectrometer detection system, the main areas of application can be divided into: biomedical, gem identification, nano-materials, agricultural production, petrochemical and so on. Compared with the traditional fluorescence spectrometer, 405nm laser-induced fluorescence spectrometer with good reproducibility, measurement speed, high sensitivity and so on. Samples can be solids, powders, meltsheets, liquids and the like. LIFS-405 series laser-induced fluorescence spectrometer detection system is divided into three models, namely LIFS-405-S, LIFS-405-M, LIFS-405-L. Customers according to their own needs, to choose the most suitable model. Features: 1. Semiconductor pump 405nm laser, small size, low power consumption 2. High spatial resolution: the measurement results up to the order of microns 3. High sensitivity: detection limit can reach 106 particles / Cm3 4 stability of 2% RMS 5.5,000.00 hours of life 6. Millisecond spectrum acquisition speed 7. 0 ~ 100mW, laser power adjustable, more efficient use 8. Solid, liquid, powder can be detected Confocal design, OD3 filtering effect 10. To a certain extent, support qualitative analysis and quantitative analysis Technical Parameters: Machine size: 300 × 200 × 62 mm Probe Fiber Configuration: Exciter: 100 μm UV-VIS Receiver: 200 μm UV-VIS Output interface: SMA905 Performance parameters: Spectral range: 420 ~ 1000nm Wavelength resolution: ~ 1.69nm Wavelength stability: <0.01nm / ℃ (standard) Excitation wavelength: 405 ± 3nm, line width <2nm Laser noise: <= 3% RMS (10Hz-100MHz) Laser power stability: ≤ 2% RMS (@ 2hrs) Laser life: 5,000.00hrs Supply voltage: 15W @ 220V Output power: 0-100mW adjustable Integration time: 1ms ~ 2min Filter laser cut-off depth: OD3 Probe focal length: 7.5mm Environmental parameters: Working / storage temperature: 0 ~ 45 ℃ Working / storage humidity 5% -80%
Introduction: LIFS-405 series laser-induced fluorescence spectrometer detection system, the main areas of application can be divided into: biomedical, gem identification, nano-materials, agricultural production, petrochemical and so on. Compared with the traditional fluorescence spectrometer, 405nm laser-induced fluorescence spectrometer with good reproducibility, measurement speed, high sensitivity and so on. Samples can be solids, powders, meltsheets, liquids and the like. LIFS-405 series laser-induced fluorescence spectrometer detection system is divided into three models, namely LIFS-405-S, LIFS-405-M, LIFS-405-L. Customers according to their own needs, to choose the most suitable model.