Brief introduction: KY - 200 micro coulomb titration is according to the principle of micro coulomb, various forms of sulfur in the sample (chloride) into sulfur dioxide in nitrogen and oxygen in high temperatures (all become HCL), enter the titration pool, iodine by electrolysis reaction with sulfur dioxide (in the pool by electrolytic silver ion and chloride ion reaction), microcomputer according to produce iodine consumption of electricity, (microcomputer according to the consumption of silver ions produced electricity), based on Faraday's law, automatically calculate the sulfur content in the samples (total chlorine content). The whole analysis process is controlled by computer, sample by automatic loading, high degree of automation instrument. Features: 1. The latest digital coulomb meter, the most complete configuration, the most widely used measure of sulphur (chloride). 2. The state of computer process control, display, parameter and print all kinds of results. 3. The operation is simple, reliable performance, good stability, easy installation, pyrolysis system for air cooling, automatic start-stop fan. Technical parameters: Sample types: liquid, solid and gas (with corresponding sampler) Method: micro coulomb method bias range: 0 ∽ 500 mv Measuring range: sulfur: 0.2 mg/L ∽ 10000 mg/L chloride: 0.3 mg/L ∽ 10000 mg/L Repeatability error: sulfur, for example: X 1.0 mg/L or less < 50%; 1.0 mg/L < X 10 mg/L or less < 20% X > 10 mg/L < 10% Gas source: oxygen and nitrogen Temperature control range: ∽ at room temperature 1000 ℃ temperature control precision: + / - 5 ℃ Power: 1500 w shape size: 530 * 500 * 500 (mm) System configuration: The normal configuration: KY - 200 liquid full, computer analysis system. Other optional parts: solid sampler, light and heavy stone cracking pipe and all kinds of the prototype.
Brief introduction: KY - 200 micro coulomb titration is according to the principle of micro coulomb, various forms of sulfur in the sample (chloride) into sulfur dioxide in nitrogen and oxygen in high temperatures (all become HCL), enter the titration pool, iodine by electrolysis reaction with sulfur dioxide (in the pool by electrolytic silver ion and chloride ion reaction), microcomputer according to produce iodine consumption of electricity, (microcomputer according to the consumption of silver ions produced electricity), based on Faraday's law, automatically calculate the sulfur content in the samples (total chlorine content). The whole analysis process is controlled by computer, sample by automatic loading, high degree of automation instrument.