1 Sales KHCOD-8G High Chlorine Wastewater Standard COD Digestion Device,Manufacturer
Position: Home > > Environmental monitoring and analysis > Water organic pollutants > COD digestion > KHCOD-8G High Chlorine Wastewater Standard COD Digestion Device

KHCOD-8G High Chlorine Wastewater Standard COD Digestion Device

Product ID:HSYJcodx039

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberKHCOD-8G
    Brand NameTAIZHOUYINHE
    Payment TermsTT,PAYPAL
    KHCOD-8G High Chlorine Wastewater Standard COD Digestion Device
    Introduction:
    The KHCOD-8G high chloride wastewater standard COD digestion device adopts microcomputer technology for timed control of the heating plate, which can simultaneously heat and digest 8 250ml conical flask reflux devices.
    The instrument uses a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can save water and standardize the instrument. Chemical solution preparation, operation, and COD calculation of the instrument.
    Suitable for the determination of COD in wastewater from oil fields, coastal oil refineries, oil depots, chlor alkali plants, and deep-sea wastewater discharge.
    Technical parameters:
    1. Anti chlorine interference: 1000~20000mg/L
    Nitrogen flow rate: 6-60mL/min
    3. Measurement range: ≤ 1000mg/L (greater than dilution)
    4. Digestion time: 2 hours and 30 minutes (time adjustable)
    5. Digestion volume: 250mL
    6. Measurement error: ≤ 500mg/L, relative standard deviation not greater than 5.0;
    ≤ 1000mg/L, relative standard deviation not greater than 8.0%
    7. Heating power: 1600W (220V, 50HZ)
    8. Cooling method: dual fan air cooling and water cooling
    9. Heating table of microcrystalline plate, making 8 samples

  • Introduction:
    The KHCOD-8G high chloride wastewater standard COD digestion device adopts microcomputer technology for timed control of the heating plate, which can simultaneously heat and digest 8 250ml conical flask reflux devices.
    The instrument uses a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can save water and standardize the instrument. Chemical solution preparation, operation, and COD calculation of the instrument.
    Suitable for the determination of COD in wastewater from oil fields, coastal oil refineries, oil depots, chlor alkali plants, and deep-sea wastewater discharge.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com