KE-B1100 Wall Mount Oxygen Analyzer Features:
1. Chinese and English menu switching function, the operation is convenient.
2. It adopts imported fuel cell oxygen sensor, which has the characteristics of long service life, fast response time, high detection accuracy and long calibration period.
3. Using a unique protective gas path to effectively protect the sensor and prevent the sensor from affecting the life of the sensor due to prolonged exposure to the air;
4. It can be calibrated at any point in the range, and the measurement accuracy of the whole range can be satisfied without multi-point calibration;
5. Built-in temperature compensation function to eliminate the influence of ambient temperature change on sensor measurement accuracy;
6. Automatic data storage function, and can access historical data at any time;
7. Automatic backflush function (optional) to avoid blockage of sampling pipeline (especially filter) caused by dust and other pollutants in the sample gas;
8. Built-in inlet pump (optional). Technical Parameters:
Measuring principle: electrochemical principle
Display mode: LCD display
Measuring range: O2 0-10/100/1000ppm/1%/5%/25% (range optional)
Measurement accuracy: ≤±2%F.S
Resolution: 0.1PPm/1PPm/0.01%/0.1%
Repeatability: ≤±1%F.S
Response time: T90≤60S
Analog output: 4~20Ma/0-5V
Working power: 100 ~ 240VAC 50 / 60Hz 1A
Ambient temperature: -5 ° C ~ +45 ° C
Sampling method: removable
Sample gas flow: 450ml ± 50ml
Working pressure (with pump): micro positive pressure / micro negative pressure / normal pressure
Working pressure (no pump): 0.1MPa~0.25MPa
Background gas: a mixture of N2/H2/Ar2/CO2 and inert gas
Dimensions: 400mm × 300mm × 200mm (height × width × depth)
Installation method: wall mounting
Features:
1. Chinese and English menu switching function, the operation is convenient.
2. It adopts imported fuel cell oxygen sensor, which has the characteristics of long service life, fast response time, high detection accuracy and long calibration period.
3. Using a unique protective gas path to effectively protect the sensor and prevent the sensor from affecting the life of the sensor due to prolonged exposure to the air;
4. It can be calibrated at any point in the range, and the measurement accuracy of the whole range can be satisfied without multi-point calibration;
5. Built-in temperature compensation function to eliminate the influence of ambient temperature change on sensor measurement accuracy;
6. Automatic data storage function, and can access historical data at any time;
7. Automatic backflush function (optional) to avoid blockage of sampling pipeline (especially filter) caused by dust and other pollutants in the sample gas;
8. Built-in inlet pump (optional).