1 Sales KD-H1473-automatic lubricating oil oxidation stability tester,Manufacturer
Position: Home > > Industry specific instrument > Oil special analytical instrument > Lubricating oil detection > KD-H1473-automatic lubricating oil oxidation stability tester for Lubricant quality analysis

KD-H1473-automatic lubricating oil oxidation stability tester for Lubricant quality analysis

Product ID:HZSYrhy020

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberKD-H1473
    Brand NameCSKDHKRYQ
    Payment TermsT/T, paypal
    Brief introduction:
    A new generation of automatic lubricating oil oxidation stability tester (rotary oxygen bomb method) adopts metal bath instead of traditional oil bath heating to reduce the harm of lampblack to human body, and small size, easy to operate, clean and environmental protection. Also equipped with automatic purge air waiting point. Secondly, it is small in size and can be directly operated on the test bench.
    Technical parameters:
    1. Applicable standards: SH/T0193, ASTMD2112, ASTMD2272.
    2. Instrument form: double bomb operation, desktop.
    3, temperature control temperature: 0 ~ 160 ℃, temperature control precision of 0.1 ℃.
    4. Display: large LCD screen.
    5. Display content: LCD screen interface:
    Control temperature and set temperature;
    Log curve of time/pressure;
    The trouble prompt and so on.
    6. Pressure detection accuracy: 0.1%
    7. Power consumption: 2.6kw
    8. The instrument is controlled by a microcomputer, which can carry out two sets of tests at the same time. The whole test process and the printing of the measured data are carried out automatically.
    9. Large screen Chinese interface, hyperbolic screen display (including temperature control, pressure curve, test data, etc.), the whole test process is clear at a glance.
    10, the instrument has automatic pressure, automatic purging, greatly saving the workload of operators.
    11. Imported parts are used in the instrument control department to ensure the reliability of the instrument.
    12. The instrument has the function of test failure and fault alarm display, which is convenient for fault diagnosis.
    13. Convenient removal of oxygen bomb without leakage.
    14. The instrument is equipped with automatic protection function. When the temperature exceeds the upper limit, the system will automatically alarm and cut off the source.
    15. Safety door is equipped before heating bath, which is convenient to place accessories and samples.
    16. The pressure transmitter is directly installed on the oxygen bomb to avoid air leakage in the hose connection.
     
  • Brief introduction:
    A new generation of automatic lubricating oil oxidation stability tester (rotary oxygen bomb method) adopts metal bath instead of traditional oil bath heating to reduce the harm of lampblack to human body, and small size, easy to operate, clean and environmental protection. Also equipped with automatic purge air waiting point. Secondly, it is small in size and can be directly operated on the test bench.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com