Position: Home > > Physical property test > Surface physical property test > Specific surface and pore size analyzer > JW-TB400 specific surface area and pore size analyzer

JW-TB400 specific surface area and pore size analyzer

Product ID:WBbbm038

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberJW-TB400
    Brand NameJINGWEIGAOBO
    Payment TermsTT,PAYPAL
    JW-TB400 specific surface area and pore size analyzer
    characteristic:
    1. High testing efficiency
    Up to four samples can be analyzed simultaneously, using unique Vtech control technology to achieve a BET specific surface area testing efficiency of up to 20 minutes per sample, meeting the usage requirements of customers with high testing volume demands in production, scientific research, and other fields.
    2. Low temperature cold bath system
    Users can choose a low-temperature cold bath system, and Sync software has compatible settings for low-temperature cold baths, making it convenient for users to test adsorption isotherms at different temperatures.
    3. Real time monitoring of P0
    Configure an independent P0 sensor to achieve real-time monitoring of p0 during the testing process, eliminating the influence of environmental temperature and atmospheric pressure on experimental results.
    4. Visual display of operating status
    The front panel of the instrument is equipped with a status display system, which displays the working principle diagram of the instrument. LED lights are added to each valve position to indicate the on/off status of the solenoid valve, allowing for intuitive judgment of the instrument's operation during the experiment.
    5. Can be integrated and remotely accessed
    The instrument communication interface is a LAN port, which can realize centralized control of one computer as the upper computer, and can remotely access and control the upper computer.
    6. Independent vacuum degassing system
    Equipped with a fully independent vacuum degassing system, it can simultaneously perform vacuum heating and degassing pretreatment on 4 samples. At the same time as sample degassing, the TB instrument host can perform adsorption testing on additional samples with high testing efficiency.
    7. Security protection mechanism
    To ensure the safety of users' use,
    (1) Develop independent safety protection software that can remotely monitor the operation status of instruments. When the instrument encounters danger such as abnormal pressure, it will automatically control the instrument, relieve the abnormal conditions that cause danger, and protect the safety of the instrument and operators.
    (2) Add a protective cover for the Dewar flask to prevent the risk of splashing low-temperature liquids such as liquid nitrogen during instrument operation.
    8. Multi way intake
    Users can choose multiple intake options, making it convenient for them to freely switch between various adsorbed gases.
    Workstation options: Users can choose 4, 8, or 12 workstations to improve testing efficiency.
    Technical parameters:
    Model: TB400
    Test principle: Static capacity method for gas adsorption
    Adsorbent gases: Non corrosive gases such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc
    Analysis port: 1-4 samples tested simultaneously
    Pressure sensors: 1000torr, 4 pieces
    Specific surface area range: 0.0005m2/g to unknown upper limit; Standard sample repeatability (RSD) ≤± 1.0%;
    Aperture range: 0.35nm-500nm; Accurate analysis of mesopores and macropores; Aperture repeatability (SD) ≤ 0.2nm;
    Pore volume range: 0.0001 cm3/g
    Degassing station: equipped with an external 4-station vacuum heating degassing machine, with a maximum temperature of 400
    Degassing temperature: room temperature -400 , accuracy ± 1
    Vacuum pump: Double stage rotary vane mechanical vacuum pump, ultimate vacuum 6.7 * 10-1Pa
    Host specifications: length 510mm x width 530mm x height 930mm, weight approximately 40 Kg
    Environmental temperature requirement: 15-35
    Environmental humidity requirement: 20% -80%, non condensing environmental humidity
    Power requirements: AC 220V ± 20V, 50/60HZ, maximum power 300W;
    Recommended application areas: battery positive and negative electrode materials, pharmaceutical excipients such as starch, porous powders such as carbon black, white carbon black, titanium dioxide, etc; Catalytic materials such as alumina and molecular sieves; Adsorption materials such as activated carbon and zeolite;

     
     
  • characteristic:
    1. High testing efficiency
    Up to four samples can be analyzed simultaneously, using unique Vtech control technology to achieve a BET specific surface area testing efficiency of up to 20 minutes per sample, meeting the usage requirements of customers with high testing volume demands in production, scientific research, and other fields.
    2. Low temperature cold bath system
    Users can choose a low-temperature cold bath system, and Sync software has compatible settings for low-temperature cold baths, making it convenient for users to test adsorption isotherms at different temperatures.
    3. Real time monitoring of P0
    Configure an independent P0 sensor to achieve real-time monitoring of p0 during the testing process, eliminating the influence of environmental temperature and atmospheric pressure on experimental results.
    4. Visual display of operating status
    The front panel of the instrument is equipped with a status display system, which displays the working principle diagram of the instrument. LED lights are added to each valve position to indicate the on/off status of the solenoid valve, allowing for intuitive judgment of the instrument's operation during the experiment.
    5. Can be integrated and remotely accessed
    The instrument communication interface is a LAN port, which can realize centralized control of one computer as the upper computer, and can remotely access and control the upper computer.
    6. Independent vacuum degassing system
    Equipped with a fully independent vacuum degassing system, it can simultaneously perform vacuum heating and degassing pretreatment on 4 samples. At the same time as sample degassing, the TB instrument host can perform adsorption testing on additional samples with high testing efficiency.
    7. Security protection mechanism
    To ensure the safety of users' use,
    (1) Develop independent safety protection software that can remotely monitor the operation status of instruments. When the instrument encounters danger such as abnormal pressure, it will automatically control the instrument, relieve the abnormal conditions that cause danger, and protect the safety of the instrument and operators.
    (2) Add a protective cover for the Dewar flask to prevent the risk of splashing low-temperature liquids such as liquid nitrogen during instrument operation.
    8. Multi way intake
    Users can choose multiple intake options, making it convenient for them to freely switch between various adsorbed gases.
    Workstation options: Users can choose 4, 8, or 12 workstations to improve testing efficiency.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com