1
Application | |
Auto analysis the oxygen content of exhaust gas for Thermoelectricity, Heat Supply, Building Material, Electron, Power, Industrial Boiler & all kinds of combustion system | |
Technical Parameter | |
Measuring Range: | 0.0-20.6% |
Accuracy: | ±2% F.S |
Stability: | Zero Drift: ±1% FS/7d |
Span Drift: ±1% FS/7d | |
Response Time: | ≤8 (T90) |
Flue Gas Temperature: | ≤800℃ (Choosable for High Temperature) |
Flue Gas Pressure: | -10~ +10Kpa |
Flue Gas Flow: | 0 ~ 50m/S |
Work Temperature: | ——40 ~ 80℃ |
Probe Material: | SUS316L |
IP Class: | IP66 |
Explosion-Proof Class: | ExdIICT6 |
Probe Length: | 0.4m, 0.6m, 0.8m, 1.0m, 1.2m, 1.5m (or as client's request) |
Insulate Current: | (0/4~20) mA (500Ω) |
Features | |
Heat resistant, corrosion resistant sensor, high reliable performance | |
Unique physical design, automatic convection without air pump and reference gas | |
Sensor with standard interface, can calibrate and test in work place, easy maintenance | |
Controlled by SCM, quick response, correct detection and reliable performance |