Introduction: The box of the operation box and the gas circulation purification system form a tight working space. The inert gas (such as argon or nitrogen) is first introduced into the box and the harmful components (such as oxygen molecules, water molecules, etc.) are removed from the box. This process is commonly called “washing”. Then, through the circulating purification system, the gas in the tank is further treated to remove trace amounts of harmful components (such as water, oxygen, organic solvents, and other active substances), so that the water and oxygen content in the operation box can reach 1 ppm or less. Features: 1. Oxygen removal of water and organic solvent function The inert gas in the glove box is circulated and circulated through the circulation fan and the purifier, continuously removing water and eliminating oxygen 2. Purification material automatic reduction regeneration function The water removal and oxygen removal materials can be regenerated and reduced, and the regeneration and reduction processes are controlled by the program. 3. Cabinet gas automatic cleaning function The atmosphere inside the glove box is completed by an automatically controlled cleaning valve 4. Large vacuum transition chamber automatic vacuum cleaning function The gas in the large transition tank is automatically cleaned by high vacuum solenoid valve and vacuum pump through vacuum displacement. 5. Box pressure automatic control function The pressure inside the glove box is automatically controlled by the PLC. The working pressure can be freely set within +/- 10 mbar and is controlled within the set range. Over +/- 12 mbar system automatically protects 6. Vacuum pump automatic control function Vacuum pump automatically turns on when needed and can be started separately 7. Atmosphere maintenance function This function can maintain the oxygen content in the box within the set range, higher than the set upper limit, the system automatically starts the cycle purification system, reaches the set lower limit, the cycle purification system automatically stops 8. The system has the function of self-detecting leak rate using oxygen method. Technical Parameters: Water content <1ppm (up to 0.1ppm in standard condition, empty tank operation) Oxygen content <1ppm (up to 0.1ppm in standard operation) Leakage rate: <0.005VOL%/H, measured value<0.001VOL%/H Product Size: L*W*H=1220*750*900mm (JMS-1X 2 gloves, single-sided operation) L*W*H=1220*1100*900mm (JMS-D1X 4 gloves, opposite operation) L*W*H=1500*750*900mm (JMS-2X 3 gloves, single-sided operation) L*W*H=1800*750*900mm (JMS-3X 4 gloves, single-sided operation) L*W*H=2440*750*900mm (JMS-S1X 4 gloves, single-sided operation)
Introduction: The box of the operation box and the gas circulation purification system form a tight working space. The inert gas (such as argon or nitrogen) is first introduced into the box and the harmful components (such as oxygen molecules, water molecules, etc.) are removed from the box. This process is commonly called “washing”. Then, through the circulating purification system, the gas in the tank is further treated to remove trace amounts of harmful components (such as water, oxygen, organic solvents, and other active substances), so that the water and oxygen content in the operation box can reach 1 ppm or less.