1 Sales ID50L500P 50mm DAC system,Manufacturer
Position: Home > > Analytical instruments > Chromatogram > Axial compression system > ID50L500P 50mm DAC system

ID50L500P 50mm DAC system

Product ID:FSzy006

Price: Please inquire PDF Format
Supply Ability:30SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberID50L500P
    Brand NameBEIJINGCHUANGXINTONGHENG
    Payment TermsT/T, paypal
    ID50L500P 50mm DAC system
    Introduction
    The 50mm pilot-scale amplification system is equipped with a dynamic axial compression column. The preparation column and the packing system are designed in one piece. The packing process is very simple. The 10μm packing can achieve almost the same high efficiency as the analytical column. It can be used online without disassembly, and always maintains axial dynamic pressure inside the column bed. It can keep the column bed and column efficiency stable for a long time. The single sample loading can reach gram level. This product is very suitable for colleges and universities. Purified monomers such as factories and scientific research units are used for structural identification. 
    Features
    (1) The column is convenient, and the operator can install the column by himself.
    (2) The column performance is maintained for a long time, and the column has a long service life.
    (3) The loading amount can reach the gram level.
    (4) The whole system is easy to move and can adapt to the experimental work in different locations.
    (5) Dynamic axial compression column can be customized according to user needs.
    (6) The injection mode can be selected as a separate injection pump or injection valve.
    (7) The maximum and minimum pressures are adjustable, the pump is stopped immediately above the maximum pressure, and the pump is automatically stopped below the minimum pressure delay of 2 minutes.
    (8) The device can be automatically or manually collected according to user requirements. 
    Technical Parameters
    Column: (1) The inner diameter of the column tube is 50mm and the length is 500mm (standard);
    (2) Column tube material: 316L stainless steel
    (3) inner wall smoothness Ra≤0.4μm;
    (4) Piston material: 316L stainless steel
    (5) Sieve plate material: 316L stainless steel, aperture: 3-5μm
    (6) Maximum withstand voltage: 10MPa
    (7) Air pressure demand: ≥0.8MPa
    (8) Gas demand: ≥3m3
    Pump:
    (1) Infusion method: double plunger reciprocating pump
    (2) Pump head: 100mL stainless steel pump head or 250mL stainless steel pump head
    (3) Maximum working pressure: 20MPa
    (4) Flow range: (0 ~ 100) mL / min or (0 ~ 250) mL / min
    (5) Flow accuracy: ±1.5%
    (6) Flow repeatability: RSD ≤ 1.0%
    (7) Working mode: isocratic or gradient
    Detector:
    (1) Wavelength range: (190 ~ 700) nm
    (2) Light source: xenon lamp (standard configuration); tungsten lamp (replaceable)
    (3) Wavelength accuracy: ±2nm
    (4) Wavelength repeatability: 0.4 nm
    (5) Detection range: (0~2) AU
    (6) Baseline noise: 3 X 10-5 AU
    (7) Baseline drift: 1 X 10-3 AU/h
    4) Application fields
    Drug purification: synthetic drugs, fermented drugs, biopharmaceuticals, etc.
    Natural product purification
    Fine chemical intermediate purification
    5) Common consumables:
    100ml pump head
    Plunger seal 6.35 (X551691) (black)
    Plunger 6.35 × 43 (finished product)
    Low pressure seal 6.35 (X225711)
    UV3000 detector xenon lamp
    250ml pump head
    250mL pump high pressure seal
    250mL pump high pressure seal
    100ml check valve
    UV3000 detector xenon lamp
    50DAC
    50 column tube seal
    50 axial column piston seal
    Balseal seal X227174 50 axial compression
    50 axial column large seal (9mm thick F4)

  • Introduction
    The 50mm pilot-scale amplification system is equipped with a dynamic axial compression column. The preparation column and the packing system are designed in one piece. The packing process is very simple. The 10μm packing can achieve almost the same high efficiency as the analytical column. It can be used online without disassembly, and always maintains axial dynamic pressure inside the column bed. It can keep the column bed and column efficiency stable for a long time. The single sample loading can reach gram level. This product is very suitable for colleges and universities. Purified monomers such as factories and scientific research units are used for structural identification. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com