ID100L650P 100mm DAC system Introduction
The 100mm pilot-scale amplification system equipped with a dynamic axial compression column uses H-TREE's patented distribution design for better separation. The preparation column and the packing system are designed in one piece. The packing process is very simple. The 10μm packing can achieve almost the same high efficiency as the analytical column. After the column is installed, it can be used online without disassembly, and the shaft is always kept inside the column bed. The dynamic pressure can keep the column bed and column efficiency stable for a long time, and the single sample loading can reach about 5g. This product is very suitable for customers who need to prepare a small amount of pure products. Features
(1) The column is convenient, and the operator can install the column by himself.
(2) The column performance is maintained for a long time, and the column has a long service life.
(3) Using the H-TREE patented distribution design, the separation effect is better
(4) The whole system is easy to move and can adapt to the experimental work in different locations.
(5) Dynamic axial compression column is customized according to user requirements.
(6) The injection mode can be selected as a separate injection pump or injection valve.
(7) The maximum and minimum pressures are adjustable, the pump is stopped immediately above the maximum pressure, and the pump is automatically stopped below the minimum pressure delay of 2 minutes.
(8) The device can be automatically or manually collected according to user requirements. Technical Parameters
Column: (1) The inner diameter of the column tube is 100mm and the length is 650mm (standard);
(2) Column tube material: 316L stainless steel
(3) inner wall smoothness Ra≤0.4μm;
(4) Piston material: 316L stainless steel
(5) Sieve plate material: 316L stainless steel, aperture: 3-5μm
(6) Maximum withstand voltage: 10MPa
(7) Air pressure demand: ≥0.8MPa
(8) Gas demand: ≥3m3
Pump:
(1) Infusion method: double plunger reciprocating pump
(2) Pump head: 500mL stainless steel pump head
(3) Maximum working pressure: 10MPa
(4) Flow range (0 to 500) mL/min
(5) Flow accuracy: ±1.5%
(6) Flow repeatability: RSD ≤ 1.0%
(7) Working mode: isocratic or gradient
Detector:
(1) Wavelength range: (190 ~ 700) nm
(2) Light source: xenon lamp (standard configuration); tungsten lamp (replaceable)
(3) Wavelength accuracy: ±2nm
(4) Wavelength repeatability: 0.4 nm
(5) Detection range: (0~2) AU
(6) Baseline noise: 3 X 10-5 AU
(7) Baseline drift: 1 X 10-3 AU/h
Common consumables (optional)
500mL pump high pressure seal
500mL pump high pressure seal
100ml check valve
UV3000 detector xenon lamp
100A column bottom seal
Balseal seal X219208, 100 axial compression
100A lower piston seal
100A column bottom seal
100A column bottom sieve plate seal
Introduction
The 100mm pilot-scale amplification system equipped with a dynamic axial compression column uses H-TREE's patented distribution design for better separation. The preparation column and the packing system are designed in one piece. The packing process is very simple. The 10μm packing can achieve almost the same high efficiency as the analytical column. After the column is installed, it can be used online without disassembly, and the shaft is always kept inside the column bed. The dynamic pressure can keep the column bed and column efficiency stable for a long time, and the single sample loading can reach about 5g. This product is very suitable for customers who need to prepare a small amount of pure products.