Introduction:
Shaking table is used to simulate the environment of electrician, electronics, automotive parts and other products and goods involved in transportation, and to test the vibration resistance of their products. All the functions required to achieve the vibration test: sine wave, frequency modulation, frequency sweep, programmable, frequency multiplication, logarithmic, maximum acceleration, amplitude modulation, time control, full-function computer control through upgrade, simple constant acceleration/definite amplitude. The equipment has been tested continuously for 3 months without failure, with stable performance and reliable quality. Vibration direction: vertical + horizontal (in the same platform, can achieve simultaneous vibration) Technical Parameters:
Table body size L*H*Wcm: 50X45X50 automatic four-dimensional space machine shaker (up, down, left and right) (works on the same table) (the latest patent: Taiwan body plus 1 times stability)
FM range 1~600Hz/1-3000HZ/1-5000HZ: FM frequency/time/amplitude/acceleration can be set arbitrarily
Sweep range 1~600Hz/1-3000HZ/1-5000HZ: Sweep frequency/rate/time/amplitude/acceleration can be arbitrarily set. The true standard sweeps back and forth and can be cycled.
Programmable range 1~600Hz/1-3000HZ/1-5000HZ: programmable frequency/time/amplitude/acceleration can be arbitrarily set, a total of 15 segments
Frequency range 1~600Hz/1-3000HZ/1-5000HZ: frequency multiplication frequency/time/amplitude/acceleration can be arbitrarily set, a total of 15 segments
Logarithmic range 1~600Hz/1-3000HZ/1-5000HZ: Sweep frequency/rate/time/amplitude/acceleration can be arbitrarily set. The true standard sweeps back and forth and can be recycled.
Simple constant acceleration: 1~600Hz/1-3000HZ/1-5000Hz to do the sweep frequency change acceleration unchanged
Simple and fixed amplitude: 1~600Hz/1-3000HZ/1-5000Hz to do sweep frequency change amplitude unchanged
Precision: frequency can be displayed to 0.01Hz
Amplitude (adjustable range mmp-p): 0-5mm can be adjusted freely
The maximum acceleration g(m/s2): 0~20g(200m/s2) can be adjusted freely
Maximum sine wave excitation force (thrust): 2000kgf
Time Control: Can be set at any time (in seconds)
Supply voltage (V): 220±20%/(50/60Hz)
Maximum current: 10(A)
Vibration machine power: 2.2(KW)
Cooling method: natural air cooling
Temperature and humidity: temperature -10°C~+60°C/humidity 10%~95%
Noise within 60 decibels
Electromagnetic radiation: within 110 milligauss (1 meter)
Measuring instrument (optional): Displays amplitude/acceleration (optional)
There are two sets of independent output: standby another set of independent output for use
Introduction:
Shaking table is used to simulate the environment of electrician, electronics, automotive parts and other products and goods involved in transportation, and to test the vibration resistance of their products. All the functions required to achieve the vibration test: sine wave, frequency modulation, frequency sweep, programmable, frequency multiplication, logarithmic, maximum acceleration, amplitude modulation, time control, full-function computer control through upgrade, simple constant acceleration/definite amplitude. The equipment has been tested continuously for 3 months without failure, with stable performance and reliable quality. Vibration direction: vertical + horizontal (in the same platform, can achieve simultaneous vibration)