Product Overview: Tracking test (electric mark index test) is in solid insulation material on the surface, in the specified size (2 mm x 5 mm) between the platinum electrode, applying a voltage and timing (30 s) high (35 mm) drop the conductive liquid droplet volume 0.1% (NH 4 CL), to evaluate solid insulation material surface under combined electric field and damp or pollution medium leakage resistance, compared to measure its electrical mark melt index (CT1) and electric mark the index (PT1). Tracking tester (electric mark index tester) instrument is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motor, electric tools, electronic instruments, electrical instrumentation, information technology and equipment research, production and quality inspection departments, can also be applied to insulation materials, engineering plastics, electrical fittings, accessories industry. Technical parameters: 1, the electrode material : the tip - platinum metal ( platinum )
2 , electrode force : 1.0 ± 0.05N
3 , electrode distance : 4.0mm ± 0.01mm, the angle 60 ° ± 5
4, the electrode voltage : 100-600V (48 ~ 60HZ) adjustable, short-circuit current 1.0 ± 0.1A voltage drop of less than 10%
5 , dropping height: 30 ~ 40mm adjustable for
6 , drip size : 44-55 drops / 1cm3 adjustable 7 , drip Time : 30s ± 5s,
8 , drip : 0 ~ 9999 times adjustable
9 , leakage judgment: the loop current is greater than 0.5A and maintained for 2 seconds then cut off the current relay , indicating samples failed
10 , the testing process: test procedures automatic control, independent ventilation
11, the reference standard : IEC60112, GB / T4207, GB4706.1
12 , the studio volume : 0.1m3 ( can be customized according to different criteria 0.5 m3 or 0.75m3)
13 , the device outside dimensions : 630mm × 750mm wide × 390mm deep high
Product Overview: Tracking test (electric mark index test) is in solid insulation material on the surface, in the specified size (2 mm x 5 mm) between the platinum electrode, applying a voltage and timing (30 s) high (35 mm) drop the conductive liquid droplet volume 0.1% (NH 4 CL), to evaluate solid insulation material surface under combined electric field and damp or pollution medium leakage resistance, compared to measure its electrical mark melt index (CT1) and electric mark the index (PT1). Tracking tester (electric mark index tester) instrument is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motor, electric tools, electronic instruments, electrical instrumentation, information technology and equipment research, production and quality inspection departments, can also be applied to insulation materials, engineering plastics, electrical fittings, accessories industry.