Product application: Used in microorganism inoculation experiment for rapid sterilization of needle, ring sterilizing equipment; Replace wine lamp, methane and other open fire sterilization methods (unsafe, slow, etc.) Safety cabinets and other equipment prohibited open fire; Use environment: safe cabinets, clean table, operating platform, such as unrestricted; Application: microbe inoculation, sputum smear drying, other needs of rapid high temperature sterilization experiments. Product features: 1, Design three inoculation rods, can be arbitrarily matched with different or the same type of needle, ring at the same time recycling; 2, Each sterilization time is about 5S, do not need to wait, do not need to prepare in advance preheating; 3, Contact module low DC voltage control, No potential safety risks; 4, The allocation of infrared high temperature sterilization zone, for the rapid sterilization of test tube mouth and test tube caliber is not limited; 5, Abandoned the traditional wine essence lamp, Benson lamp and other defects of open fire (unsafe, It is strictly forbidden to use in the safety cabinet; 6, The resistance type infrared sterilizer (small microphone type) is abandoned with short life, long preheating time, inconvenient sterilization to the test tube mouth, no quantitative needle and ring. 7, This product is equipped with professional standardized quantitative ring, When used, it is not necessary to make the inoculation ring itself, which is convenient and practical. 8, The sterilization process is completely in accordance with the requirements of microbiological characteristics, which can prevent the spatter of microorganisms or secretions containing water. 9. The national exclusive access to the products of the State Class II Medical device Registration Group, Safety is trustworthy! Technical specifications: Type: HT-103CN Infrared lamp temperature (vertical distance above lamp tube 50ww):900 ℃) Inoculation needle, ring sterilization temperature: 700 ℃ LCD screen display: temperature, humidity, working state, working current Operation key: key switch Working time: infrared light: 60S; Inoculation needle, ring: 5S Power: maximum short-time power 63OW Shape dimensions mnww: 320 × 120 × 210 Weight Kaw 2.75
Product application: Used in microorganism inoculation experiment for rapid sterilization of needle, ring sterilizing equipment; Replace wine lamp, methane and other open fire sterilization methods (unsafe, slow, etc.) Safety cabinets and other equipment prohibited open fire; Use environment: safe cabinets, clean table, operating platform, such as unrestricted; Application: microbe inoculation, sputum smear drying, other needs of rapid high temperature sterilization experiments.