Features: Adopt independent and efficient motor to supply gas, filter membrane blockage and other automatic pressure compensation, flow change <10%. Using the world famous high efficiency filter (ULPA/HEAP), the cleanliness is better than 10 levels. 6mm thick tempered glass front window, block ultraviolet rays, prevent burst, protect user safety. The height of the foot can be adjusted to 0-75mm, which can be adjusted according to the user's operating comfort height. Foot adjusting bolts are built in, no exposed threads, easy to clean and prevent microbial breeding. Use the patent technology of air block on the edge and both sides of the front window (patent number: ZL200520125549.X) to fully protect operators and experimental samples. Ultraviolet sterilization time booking function. The window operating 10 ° Angle design; Uv lamp and front window, fan, lamp interlock design, safe and seamless joint. Equipped with high precision leakage protection switch, even if there is no grounding line or abnormal user socket can be used safely. There is abnormal situation (the height of the door exceeds the limit) (the air flow fluctuation exceeds 20%) (the door is not closed properly) (the filter is blocked, damaged, short life) (the fan is closed after the door is opened) alarm Technical parameters: Model: HR60 - IIA2 Atmospheric pressure: 70~106KPa Noise (db) : less than or equal to 67 Illumination: p 1200 lx Main filter category: ULPA Personnel protection: 1.24*1000000 Main filter efficiency: 99.9995%@0.12 m Air supply velocity (m/s) : 0.32 Intake velocity (m/s) : 0.58 Exhaust air volume (m3/h) : 690 Frequency: 50 + 1 hz Studio size (width * depth * height) mm: 1735*610*680 Overall dimensions (width * depth * height) mm: 1960*780*2200 Recommended number of users: 2-3 Material: SUS304 Weight (Kg) : 328 Castor: Socket in the cabinet (number of anti-splash socket) : 1 Fixed foot: adjustable height: 75mm, no exposed thread Filter blocking alarm: yes Filter damage alarm: yes Front window glass prevents uv rays: yes
Features: Adopt independent and efficient motor to supply gas, filter membrane blockage and other automatic pressure compensation, flow change <10%. Using the world famous high efficiency filter (ULPA/HEAP), the cleanliness is better than 10 levels. 6mm thick tempered glass front window, block ultraviolet rays, prevent burst, protect user safety. The height of the foot can be adjusted to 0-75mm, which can be adjusted according to the user's operating comfort height. Foot adjusting bolts are built in, no exposed threads, easy to clean and prevent microbial breeding. Use the patent technology of air block on the edge and both sides of the front window (patent number: ZL200520125549.X) to fully protect operators and experimental samples. Ultraviolet sterilization time booking function. The window operating 10 ° Angle design; Uv lamp and front window, fan, lamp interlock design, safe and seamless joint. Equipped with high precision leakage protection switch, even if there is no grounding line or abnormal user socket can be used safely. There is abnormal situation (the height of the door exceeds the limit) (the air flow fluctuation exceeds 20%) (the door is not closed properly) (the filter is blocked, damaged, short life) (the fan is closed after the door is opened) alarm