  • Model NumberHPC518
    Brand NameYM
    Payment TermsT/T ,paypal
    Technical parameters
    1, Measurement range: 
           HC:0-10000 ×10-6 (ppm)vol( petrol, hexane equivalent ) 
           Or C3H8: 0-20000 ×10-6(ppm)vol( liquefied petroleum gas as fuel, propane equivalent )
           CO:0 ~ 10× 10-2 (% ) vol                CO2:0 ~ 20 ×10-2 (% ) vol 
           O2:~ 25 × 10-2 (% ) vol                NOx:0 ~ 5000 ×10-6 ( ppm ) vol 
           λ: 0.5~ 1.5                           COcor:0 ~ 10× 10-2 (% ) vol
           R.M.P:0-9999r.m.p                     OIL TEMP:0-150 °C 
    2, Error: HC ± 10× 10-6 (ppm)vol ( absolute error ) or± 5% ( relative error)
           CO ± 0.03× 10-2 ( % )vol ( absolute error ) or± 5% ( relative error) 
           CO2 ± 0.5× 10-2 ( % )vol ( absolute error ) or± 5% ( relative error)
           O2 ±  0.1× 10-2 ( % )vol ( absolute error ) or± 5% ( relative error) 
           NOx ± 25× 10-6 ( ppm)vol ( absolute error ) or± 4% ( relative error)
           The above error in one of the requirements to meet.
    3: Auto zero calibration, stability, moment drift≤± 3%
    4, Repeat: repeat error less than ± 2%
    5, Resolution: HC:1 ×10-6 ( ppm)vol      CO: 0.01× 10-2 ( % )vol    CO2: 0.1× 10-2 ( % )vol
                O2: 0.01× 10-2 ( % ) vol    NOx:1 ×10-6 ( ppm) vol    λ: 0.01
                R.P.M: 10r.p.m            OIL TEMP:0.1 °C
    6, 95% in response, response time less than 10 seconds
    7, The preheating time: 8min ( can be preheated 3min emergency detection )
    8, The use of environmental conditions: temperature of -5-50 °C, relative humidity 90%
    9, The oxygen sensor and the nitrogen oxygen sensor in air in life expectancy for two years and 14 months.
     ( over the duration of accuracy will drop ) 
    10, Power: built-in battery powered directly use
                      by an on-board DC12V direct power use ( without any power supply inverter )
                      AC100-240V 50/60HZ
    11, Power consumption: <50VA 
    12, Dimensions: 520mm (L)× 360mm ( W)× 250mm (H) 
     

  • Technical parameters
    1, Measurement range: 
           HC:0-10000 ×10-6 (ppm)vol( petrol, hexane equivalent ) 
           Or C3H8: 0-20000 ×10-6(ppm)vol( liquefied petroleum gas as fuel, propane equivalent )
           CO:0 ~ 10× 10-2 (% ) vol                CO2:0 ~ 20 ×10-2 (% ) vol 
           O2:~ 25 × 10-2 (% ) vol                NOx:0 ~ 5000 ×10-6 ( ppm ) vol 
           λ: 0.5~ 1.5                           COcor:0 ~ 10× 10-2 (% ) vol
           R.M.P:0-9999r.m.p                     OIL TEMP:0-150 °C 
    2, Error: HC ± 10× 10-6 (ppm)vol ( absolute error ) or± 5% ( relative error)
           CO ± 0.03× 10-2 ( % )vol ( absolute error ) or± 5% ( relative error) 
           CO2 ± 0.5× 10-2 ( % )vol ( absolute error ) or± 5% ( relative error)
           O2 ±  0.1× 10-2 ( % )vol ( absolute error ) or± 5% ( relative error) 
           NOx ± 25× 10-6 ( ppm)vol ( absolute error ) or± 4% ( relative error)
           The above error in one of the requirements to meet.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com