HPA-100 high pressure gas adsorption instrument Introduction:
HPA-100 high pressure gas adsorption instrument is a gas adsorption instrument that can take both high and low pressure ranges into consideration. It has advanced technology, excellent quality, more comprehensive theoretical model and excellent test accuracy, and meets many applications such as scientific research and academic discussion. demand Features:
1. With advanced thermostat
Configure advanced thermostatic gas path and test thermostat to solve test error caused by temperature
2. Full-featured and superior analytical performance
It can perform isothermal pressure swing adsorption under extreme vacuum (10-2Pa) to 10Mpa, and is suitable for research and development of adsorption properties of materials such as shale gas, coalbed methane, hydrogen storage materials, porous carbon and metal organic framework.
The atmospheric pressure isotherm adsorption test of low adsorption materials can be carried out to determine the adsorption properties of materials for different gases. Such as: O2 / CO2 / CO / H2 and various types of alkanes olefins
3. Configure advanced gas booster system
With the German MAXIMATOR brand, the performance is stable, small size and high safety factor. The gas pressure is doubled (the design standard of ultra-high pressure equipment), the seal is made of safe and stable PTFE material, which is easy to maintain. The system is driven by gas. The ratio of driving pressure to pressure is 1:75, and the bursting pressure is 4 times of design pressure. Safe and long service life
4. Use a variety of advanced self-control valve body to meet the needs of high and low pressure and other links
Use closed high vacuum module and pneumatic high pressure valve to meet the gas path control of different working conditions (high/low pressure) Technical Parameters:
Analytical method: vacuum static capacity method
Test data: ultimate vacuum ~10Mpa high pressure isotherm adsorption
Atmospheric pressure ~120Kpa atmospheric pressure isotherm adsorption
Analysis accuracy: repeatability error is less than ±1.5%
Number of analysis stations: 1 independently controlled analysis station
Dewar volume: 4L ultra-large capacity Dewar, no intervention for 72 hours
Sample tube volume: 10ML-50ML
Adsorbed gases: hydrogen, oxygen, carbon monoxide, carbon dioxide, methane, olefins, alkanes, etc.
Analysis temperature: -5~60°C
Sample preparation: independent sample preparation station (degassing station), with independent temperature control system and vacuum system, upper temperature limit 400 ° C
Introduction:
HPA-100 high pressure gas adsorption instrument is a gas adsorption instrument that can take both high and low pressure ranges into consideration. It has advanced technology, excellent quality, more comprehensive theoretical model and excellent test accuracy, and meets many applications such as scientific research and academic discussion. demand