    HM-NC06 pesticide residue rapid detector
    Introduction:
    HM-NC06 pesticide residue rapid detector is designed according to the national standard method (GB/T5009.199-2003) and the requirements of WHO, FAO residue pesticide testing standards, World Environmental Protection Agency EPA reference intake and other requirements. The enzyme inhibition rate colorimetric method is used to quickly and accurately detect the content of organophosphorus and carbamate pesticides in fruits, vegetables and other agricultural and forestry products. It is widely used in the rapid detection of organophosphorus and carbamate pesticide residues in foods such as vegetables, fruits, tea, grain, agricultural and sideline products; in addition, it can also be used for on-site detection of fruit and vegetable tea production bases and agricultural wholesale sales markets, restaurants, Safety quick test before processing fruits and vegetables in schools, canteens and families.
    Features:
    1. Both acetylcholinesterase and butyrylcholinesterase reagents can be used and meet the requirements of national standards and standards of the Ministry of Agriculture.
    2. Automatically judge whether the sample is qualified, and the test result is more intuitive.
    3. The instrument has a menu library of more than 100 vegetable names, which can be selected by clicking directly. And you can edit the name of the vegetable and print out the vegetable name directly.
    4. Detection channels: 6 detection channels, multiple samples can be tested at the same time, each sample is controlled by the program to work independently and will not interfere with each other.
    5. The intelligent operating system adopts more user-friendly operation. The main control adopts a multi-core processor with a main frequency of 1.88Ghz, which has a faster operating speed and stronger stability.
    6. Display mode: 7-inch true-color touch screen display, humanized Chinese operation interface, intuitive and simple reading.
    7. The printer adopts serial port 5v printing, manual printing or automatic printing can be selected, and the printing result is output in three minutes. The printing format is the name of the tester, the difference in absorbance, the test time, the test organization, the name of the sample, and the result judgment.
    8. The light source adopts imported ultra-bright light-emitting diodes, which have the advantages of low power consumption, high precision, strong stability, controllable light source, and fast response speed.
    9. The instrument has GPRS remote transmission function, can insert a mobile phone card to realize the data remote transmission platform, wifi networking function, can quickly upload data to the computer for data management and statistics.
    10. It adopts USB2.0 interface design, which is convenient for data storage and movement, and can be directly connected to the computer at any time, and the computer can be used to control the instrument. Realize data query, browsing, analysis, statistics, printing, etc.
    11. High degree of intelligence, the instrument has a self-check function: with power-on self-check and zero adjustment function, with automatic detection repeatability function
    12. The instrument has its own protection function, which can set a user name and password to prevent non-staff operation.
    13. Adopt DC12v direct current power supply, higher safety system, and equipped with 2A lithium battery charger.
    14. The instrument has the functions of recalibration, lock, and factory reset.
    technical parameter; 
    Wavelength configuration: 410nm;
    Inhibition rate display range: 0%100%;
    Inhibition rate measurement range: 0%100%;
    Transmittance accuracy: ±1.5%;
    Repeatability of transmittance: ≤0.5%;
    Drift: ≤0.005Abs/3min;
    Inhibition rate indication error: ≤10%
    Inhibition rate repeatability: ≤5%
    Optional function:
    1) It can be equipped with voice registration function and humanized guidance operation.
    3) The instrument can realize its own heating function.
    4) A large-capacity lithium battery can be configured.
     
  • Introduction:
    HM-NC06 pesticide residue rapid detector is designed according to the national standard method (GB/T5009.199-2003) and the requirements of WHO, FAO residue pesticide testing standards, World Environmental Protection Agency EPA reference intake and other requirements. The enzyme inhibition rate colorimetric method is used to quickly and accurately detect the content of organophosphorus and carbamate pesticides in fruits, vegetables and other agricultural and forestry products. It is widely used in the rapid detection of organophosphorus and carbamate pesticide residues in foods such as vegetables, fruits, tea, grain, agricultural and sideline products; in addition, it can also be used for on-site detection of fruit and vegetable tea production bases and agricultural wholesale sales markets, restaurants, Safety quick test before processing fruits and vegetables in schools, canteens and families.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com