HD-A chromatogram acquisition analyzer Introduction
Chromatography acquisition analyzer HD-A (single channel) can be connected to the UV detector at the same time; chromatogram acquisition analyzer HD-A: elution spectrum selection: for absorbance A, transmittance T%, AT% The real-time tracing is displayed, and the absorbance A value and the transmittance T% value are displayed; the calculation amount is displayed, the area map is calculated, and the calculated dimensionless quantity is used to calculate the data of the selected collection peak. Image scaling: view the absorbance A value and transmittance T% value at any point on the plotted spectrum; expand, compress, translate, save, and print the elution map; chromatogram collection: peak, peak width, peak area, Ratio of peak area to ** product, volume content, ratio of selected peak area to collection range area (collection range multiplied by peak), storage time, etc. Feature
Elution spectrum selection: for absorbance A, transmittance T%, AT% comparison real-time tracing, display absorbance A value, transmittance T% value; display calculation amount, calculate area map, calculate the dimensionless quantity To calculate the data for the selected collection peak.
Image scaling: view the absorbance A value and transmittance T% value at any point on the plotted spectrum; expand, compress, translate, save, and print the elution map;
Chromatogram collection: peak, peak width, peak area, ratio of selected peak area to ** product, volume content, ratio of selected peak area to collection range area (collection range multiplied by peak), storage time Wait
Time recording speed: experimental time prompt setting; drawing time is unlimited; calculating the area of the drawn elution spectrum; having all the functions of the recorder; linearity: less than ±0.1%;
Integral sensitivity: 1uV.sec; sampling frequency: 30 times / sec; sampled data output to Excel; map ordinate axis unit is absorbance
A map of sample separation can be automatically plotted and the distribution of the desired sample in a portion of the collector can be detected.
With USB\COM dual data port, it can be easily operated online, and WIN2000/XP/VISTA/WIN7 systems are compatible. Technical Parameters
Chromatography acquisition analyzer HD-A (single channel) can be connected to the UV detector to work simultaneously
Chromatography acquisition analyzer HD-2A (dual channel) can be connected to two UV detectors to work simultaneously
Chromatography acquisition analyzer HD-4A (four channels) can be connected to four UV detectors to work simultaneously
Interface: RS232C serial port; input: 0-10mv; can be equipped with HD-2000 UV detector and nucleic acid protein detector produced by our company;
Introduction
Chromatography acquisition analyzer HD-A (single channel) can be connected to the UV detector at the same time; chromatogram acquisition analyzer HD-A: elution spectrum selection: for absorbance A, transmittance T%, AT% The real-time tracing is displayed, and the absorbance A value and the transmittance T% value are displayed; the calculation amount is displayed, the area map is calculated, and the calculated dimensionless quantity is used to calculate the data of the selected collection peak. Image scaling: view the absorbance A value and transmittance T% value at any point on the plotted spectrum; expand, compress, translate, save, and print the elution map; chromatogram collection: peak, peak width, peak area, Ratio of peak area to ** product, volume content, ratio of selected peak area to collection range area (collection range multiplied by peak), storage time, etc.