Introduction
Nucleic Acid Protein Detector/UV Detector Series is an ultraviolet detection device for separating UV-absorbing substances (proteins, nucleic acids, peptides, enzymes) from an automatic liquid chromatography chromatograph. The principle is based on the substance (sample) to UV. The light has obvious absorption characteristics, and the ratio analysis of the sample components is realized, so as to carry out the identification detection and content determination of the sample protein and the nucleic acid substance. The optical density A value can be directly read out, and the relative peak value of each peak area can be directly recorded in the wavelength accuracy and repeatability, the monochromaticity, the qualitative and the quantitative analysis, and the relative mass content can be calculated; Peng collector, constant current pump, partial collector, gradient mixer, chromatography column, which is a complete set of automatic liquid chromatography separation and analysis device, Jia Peng can be compatible with GE Healthcare laboratory scale column interface, Pre-separation of equipment systems such as AKTA can meet the requirements of various chromatographic analysis such as gel permeation chromatography, affinity chromatography and ion exchange chromatography, and has a performance-price ratio. Features
The detector is matched with a constant flow pump and has a speed limit of 0.5-900 ml/h or 1-14500 ml/h.
Clear LED display mode, new microcomputer chip control, display 3 OD values, user directly read the optical density A value sensitivity,
The baseline drift is small and suitable for testing experimental micro-samples.
Imported light source, the intensity of each line is uniform, and the baseline stabilization time is shorter.
Compatible with GE column interfaces for pre-separation in equipment systems such as AKTA. Technical Parameters
Product Name: Nucleic Acid Protein Detector / UV Detector
Test wavelength: 254nm, 280nm/220nm, 254nm, 280nm, 340nm
Wavelength accuracy: ±1nm
Flowable sample cell: Optical path: 3mm, volume 100ul
Transmission range: 0~100T%
Absorbance range 2A, 1 A, 0.5A, 0.2 A, 0.1 A, 0.05 A
Introduction
Nucleic Acid Protein Detector/UV Detector Series is an ultraviolet detection device for separating UV-absorbing substances (proteins, nucleic acids, peptides, enzymes) from an automatic liquid chromatography chromatograph. The principle is based on the substance (sample) to UV. The light has obvious absorption characteristics, and the ratio analysis of the sample components is realized, so as to carry out the identification detection and content determination of the sample protein and the nucleic acid substance. The optical density A value can be directly read out, and the relative peak value of each peak area can be directly recorded in the wavelength accuracy and repeatability, the monochromaticity, the qualitative and the quantitative analysis, and the relative mass content can be calculated; Peng collector, constant current pump, partial collector, gradient mixer, chromatography column, which is a complete set of automatic liquid chromatography separation and analysis device, Jia Peng can be compatible with GE Healthcare laboratory scale column interface, Pre-separation of equipment systems such as AKTA can meet the requirements of various chromatographic analysis such as gel permeation chromatography, affinity chromatography and ion exchange chromatography, and has a performance-price ratio.