Introduction: HD-3000N Nucleic Acid Protein Detector/UV Detector is a modern analytical laboratory instrument that is engaged in life science research, drug determination, agricultural scientific research, chemical engineering, food science, universities and medical institutions. The nucleic acid protein detector/UV detector series is an ultraviolet detection device for separating ultraviolet absorbing substances (proteins, nucleic acids, polypeptides, enzymes) from an automated liquid chromatography separation chromatography. The principle is based on the substance (sample) pair. Ultraviolet light has obvious absorption characteristics, so that the analysis of the content of the sample components can be performed in order to carry out the identification and detection of the sample protein and nucleic acid substances and the determination of the content. Optical density A can be read directly, and the wavelength accuracy and repeatability are high, the monochromaticity is good, the relative peak surface value of each peak area can be directly recorded in qualitative and quantitative analysis, and the relative amount of the mass can be calculated; Jiapeng collector, constant current pump, partial collector, gradient mixer, and chromatography column constitute a complete set of automatic liquid chromatography separation and analysis device. Jiapeng can be fully interfaced with GE Healthcare's lab-scale chromatography column. Compatible, it can be pre-separated in equipment systems such as AKTA without any connection, and it can meet the requirements of gel chromatography, affinity chromatography, ion exchange chromatography and other chromatographic analysis, with extremely high performance price ratio. Nucleic acid protein detector/UV detector series products have a small sample cell for continuous detection function. During column chromatography separation and analysis, the eluent flows through Jiapeng sample cell, and the chromatogram acquisition apparatus can automatically draw the sample separation. The spectrum (absorption peaks or transmission peaks), at the same time, can detect the distribution of the desired sample in a part of the collector tube, and monitor the column chromatography process at any time, especially during the exploratory experiment, and change the elution conditions in time. In order to quickly obtain the best experimental program, the final separation of biological macromolecules. The ideal instrument for scientific research and production by scientific research institutes, factories and mines, is widely used by famous universities and colleges such as Tsinghua University, Peking University and Fudan University. Features: 1. Instrument built-in data acquisition system, the latest integrated circuit, smart microcontroller, international factory components, high sensitivity ultraviolet light source photomultiplier tube. 2. Full-screen 5-inch touch color screen, auto-zero, no need to manually select the range. 3. The HD-3000N is fully compatible with GE Healthcare's lab-scale column interface and does not require any connectors to perform pre-separation on AKTA and other equipment systems. 4. Automatically select the color screen sample separation pattern, which can be stored and can be saved. 5 computer nucleic acid protein detector HD-3000N type liquid crystal display 4 OD value, the user directly reads the optical density A value. 6. Bright adjustment: touch button continuous adjustment (domestic first) 7. Ultraviolet wavelength can be arbitrarily switched at 214,220,254,280,340 nm. 8. Using USB/COM dual data ports, XP/Win7 systems are compatible. Technical Parameters: Computer Nucleic Acid Protein Detector HD-3000N Test wavelengths: 214, 254, 280 nm Dissolve sample: 80μl Light path: 4mm Display: Full-screen 5-inch touch color screen Range: Automatic 100%-0.2 A, without manual selection Analysis software: computer graphics, data analysis, calculation and printing Computer UV Detector HD-3000N Test wavelength: 220nm, 254nm, 280nm, 340nm. Flow cell: 80μl Light path: 4mm. Display: Full-screen 5-inch touch color screen Range: Automatic 100%-0.2 A, without manual selection Analysis software: computer graphics, data analysis, calculation and printing
Introduction: HD-3000N Nucleic Acid Protein Detector/UV Detector is a modern analytical laboratory instrument that is engaged in life science research, drug determination, agricultural scientific research, chemical engineering, food science, universities and medical institutions. The nucleic acid protein detector/UV detector series is an ultraviolet detection device for separating ultraviolet absorbing substances (proteins, nucleic acids, polypeptides, enzymes) from an automated liquid chromatography separation chromatography. The principle is based on the substance (sample) pair. Ultraviolet light has obvious absorption characteristics, so that the analysis of the content of the sample components can be performed in order to carry out the identification and detection of the sample protein and nucleic acid substances and the determination of the content. Optical density A can be read directly, and the wavelength accuracy and repeatability are high, the monochromaticity is good, the relative peak surface value of each peak area can be directly recorded in qualitative and quantitative analysis, and the relative amount of the mass can be calculated; Jiapeng collector, constant current pump, partial collector, gradient mixer, and chromatography column constitute a complete set of automatic liquid chromatography separation and analysis device. Jiapeng can be fully interfaced with GE Healthcare's lab-scale chromatography column. Compatible, it can be pre-separated in equipment systems such as AKTA without any connection, and it can meet the requirements of gel chromatography, affinity chromatography, ion exchange chromatography and other chromatographic analysis, with extremely high performance price ratio. Nucleic acid protein detector/UV detector series products have a small sample cell for continuous detection function. During column chromatography separation and analysis, the eluent flows through Jiapeng sample cell, and the chromatogram acquisition apparatus can automatically draw the sample separation. The spectrum (absorption peaks or transmission peaks), at the same time, can detect the distribution of the desired sample in a part of the collector tube, and monitor the column chromatography process at any time, especially during the exploratory experiment, and change the elution conditions in time. In order to quickly obtain the best experimental program, the final separation of biological macromolecules. The ideal instrument for scientific research and production by scientific research institutes, factories and mines, is widely used by famous universities and colleges such as Tsinghua University, Peking University and Fudan University.