HCA - 102 standard COD digestion for Water Quality Analysis

Product ID:HSYJcodx013

Price: Please inquire PDF Format
Supply Ability:20
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberHCA - 102
    Brand NameYM
    Payment TermsT/T western union paypal
    Brief introduction:
    HCA - 102 standard COD digestion follows the international standard (ISO) and the basic principles of national standard (GB11914-89), to ensure the micro boiling reflux heat 2 hours of operation, the preparation of the reagent solution and addition amount and gb is consistent, to ensure reliable and accurate analysis results.
    HCA - 102 standard COD digestion device adopts microcomputer technology for timing control of heating furnace, eight to 250 ml conical reflux device for heating at the same time. Achieve the purpose of energy saving, reduce power load and improve efficiency.
    Features:
    1. The new furnace set, even heating, heating surface temperature, cooling speed.
    2. The furnace plate using a new type of high temperature resistant inorganic insulation material environmental protection, thermal efficiency is higher.
    3. The flat furnace high temperature resistant glass-ceramic panel surface easy to clean.
    4. The modified return line and cooling system, ensure good digestion backflow effect as well as the result of the sample digestion parallelism.
    5. Corresponding to the user's choice of different heating power, heating surface temperature control of electric furnace.
    6. Can be set digestion time, unattended.
    7. To save electricity, water, improve the efficiency, enhanced the safety of the instrument.
    Technical parameters:
    Measuring range: 10-700 mg/L, greater than 700 mg/L water diluted
    Digestion time: 10 minutes to 2 hours and 30 minutes (the user can choose heating time)
    Measurement error: potassium hydrogen phthalate standard solution (500 mg/L), relative standard deviation is not more than 5.0%;
    Industrial organic wastewater (500 mg/L), relative standard deviation is not more than 8.0%
    Ambient temperature: 35 ℃ or less
    Digestion sample number: 8 (24 # 250 ml conical grinding at the mouth of the bottle)
    Heating power: 1600 w or less (AC 220 v, 50 hz, the user can choose heating power)
    Instrument size: 450 mm (L) X 350 mm (W) X 650 mm

  • Brief introduction:
    HCA - 102 standard COD digestion follows the international standard (ISO) and the basic principles of national standard (GB11914-89), to ensure the micro boiling reflux heat 2 hours of operation, the preparation of the reagent solution and addition amount and gb is consistent, to ensure reliable and accurate analysis results.
    HCA - 102 standard COD digestion device adopts microcomputer technology for timing control of heating furnace, eight to 250 ml conical reflux device for heating at the same time. Achieve the purpose of energy saving, reduce power load and improve efficiency.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com