HASE-06 Rapid Solvent Extraction Instrument Introduction: Compared with traditional sample extraction methods such as Soxhlet extraction and ultrasonic extraction, the rapid solvent extractor utilizes high-temperature and high-pressure conditions to quickly extract six solid or semi-solid samples, greatly reducing extraction time and solvent usage, and improving experimental efficiency. The instrument adopts a graphical extraction process interface design, which can display real-time temperature and pressure monitoring curves, making the operation simple and convenient; Multiple extraction tanks and collection bottles of different specifications can be used together to meet different sample extraction needs; Equipped with remote monitoring and automatic push notification functions, the extraction process is under control. characteristic: 1. Six channels are used in parallel at the same time, supporting independent control of grouped channels to improve the efficiency of extraction experimental processing; 2. The three-dimensional surround heating design has high heating efficiency and uniform sample heating; 3. Equipped with pre heating function, it can rise to above 125 ℃ within 5 minutes, improving experimental efficiency. 4. Graphical extraction process interface, real-time display of extraction temperature, pressure curve and other status parameters; 5. Users can query usage logs at any time and export detailed operation records from a USB flash drive; 6. Transparent and visual design, easy to observe the sample extraction situation at any time, intuitive and clear. 7. Solvent management system, supporting automatic mixing of 4 solvents in any ratio; 8. Equipped with intelligent leak detection and intelligent blockage judgment functions, the instrument automatically pauses the operation of this channel when abnormalities are detected, without affecting the normal operation of other extraction channels; 9. Equipped with remote monitoring and remote push notification information functions. 10. Various specifications of 50mL-250mL collection bottles are available for selection, without the need for sample transfer, and can be seamlessly connected with parallel concentration instruments; 11. Compatible with 10-120mL extraction cans for filling samples to meet the experimental needs of different samples. Technical parameters: Power: 2000W Touch screen: 10.1-inch high-definition color touch screen Extraction temperature: Temperature range: room temperature -200 ℃, temperature control accuracy: ± 1 ℃ Extraction pressure: Pressure range: 0-20Mpa, pressure control accuracy: ± 0.5Mpa Safety protection: Equipped with multiple safety protection alarm devices such as overtemperature, overpressure, and leakage prevention Exhaust system: equipped with strong exhaust device Working temperature/humidity: 15 ℃~40 ℃/20~80% Working voltage: AC 220V ± 10%, 50/60Hz
Introduction: Compared with traditional sample extraction methods such as Soxhlet extraction and ultrasonic extraction, the rapid solvent extractor utilizes high-temperature and high-pressure conditions to quickly extract six solid or semi-solid samples, greatly reducing extraction time and solvent usage, and improving experimental efficiency. The instrument adopts a graphical extraction process interface design, which can display real-time temperature and pressure monitoring curves, making the operation simple and convenient; Multiple extraction tanks and collection bottles of different specifications can be used together to meet different sample extraction needs; Equipped with remote monitoring and automatic push notification functions, the extraction process is under control.