H600 automatic glycosylated hemoglobin analyzer characteristic: 1. Fully modular design; 2. STAT emergency samples are inserted at any time and automatically detected; 3. High-performance LED detector, long service life, without preheating; 4. The chromatographic column heating module has the ability to control the constant temperature of the chromatographic column, the temperature control environment range is 5 ℃~40 ℃, and the temperature fluctuation is ± 0.2 ℃; HPLC pump, capable of withstanding a maximum pressure of 200kg/cm2 (2900psi), with pressure sensing capability, and pressure fluctuation of ± 1%; 5. Automatic calibration, using special calibrators, can perform automatic calibration, and can correspond to NGSP and IFCC to obtain accurate and reliable measured values. 6. Sieve plate: 250test/piece; 7. Daily maintenance is not required; 8. Automatic alarm if there is no reagent or reagent is insufficient; 9. Chromatographic column: 2000test/piece, only need to be calibrated once with calibrator. Technical parameters: Detection method: ion exchange high performance liquid chromatography (HPLC) Repeatability: ≤ 3.0% Injection method: automatic puncture injection of the original test tube, hemolysis mode injection of the sample cup, automatic detection of the original test tube and sample cup Sample capacity: 15 samples/disk, CAL1 (QC1)&CAL2 (QC2), ST emergency samples Sample type: venous whole blood, finger tip blood or hemolytic sample Test range: HbA1c: 4~17%; 20~162mmol/mol Test item: HbA1c and b thalassemia A2 Result report: IFCC and NGSP results can be reported at the same time USB interface: support computer for data communication and scanner connection
characteristic: 1. Fully modular design; 2. STAT emergency samples are inserted at any time and automatically detected; 3. High-performance LED detector, long service life, without preheating; 4. The chromatographic column heating module has the ability to control the constant temperature of the chromatographic column, the temperature control environment range is 5 ℃~40 ℃, and the temperature fluctuation is ± 0.2 ℃; HPLC pump, capable of withstanding a maximum pressure of 200kg/cm2 (2900psi), with pressure sensing capability, and pressure fluctuation of ± 1%; 5. Automatic calibration, using special calibrators, can perform automatic calibration, and can correspond to NGSP and IFCC to obtain accurate and reliable measured values. 6. Sieve plate: 250test/piece; 7. Daily maintenance is not required; 8. Automatic alarm if there is no reagent or reagent is insufficient; 9. Chromatographic column: 2000test/piece, only need to be calibrated once with calibrator.