1 Sales GOODSPE-1200 Large Flow Automatic Solid Phase Extraction,Manufacturer
Position: Home > > Lab general equipment > Separation / extraction equipment > Solid phase extraction > GOODSPE-1200 Large Flow Automatic Solid Phase Extraction for Trace organic matter extraction

GOODSPE-1200 Large Flow Automatic Solid Phase Extraction for Trace organic matter extraction

Product ID:SYFLCQgx017

Price: Please inquire PDF Format
Supply Ability:20SETS/MONTH
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGOODSPE-1200
    Brand NameSHKZ
    Payment TermsT/T, paypal
    Introduction
    One extraction channel is a 1-channel type GOODSPE-6000 automatic solid phase extraction instrument, which is cost-effective; it can process up to 20L of liquid samples for use in drinking water, surface water, groundwater, food, beverage and other sample extracts. Trace organic extraction, designed for large volumes of water analysis. Uses: 1. Environment: insecticides and herbicides, petroleum and grease, polycyclic aromatic hydrocarbons, explosives, PCBs, brominated flame retardants, dioxins, furans organic pollutants, phenyl urea, semi-volatile Organic pollutants, endocrine disruptors; 2. Food: pesticides and herbicides, contaminants in packaged beverages, pesticide residues, natural products, dietary supplements, melamine, antibiotic residues, malachite green, crystal violet , Sulfonamides, quinolones, plasticizers; 3. Pharmaceuticals: analysis of active ingredients in liquids, analysis of extractables in pharmaceutical packaging, vitamins and antibiotics; 4. Other areas:
    Tobacco analysis, flavor and fragrance analysis, cosmetics analysis, azo dye analysis, in vivo metabolism of drugs, narcotic drugs, psychotropic drugs, poison rat poison, life science;
    Features:
    1. Processing large volume samples, sample volume range 20mL-20L;
    2. Combine the column and membrane methods on the same instrument and truly use one machine (extraction column: 1ml, 3ml, 6ml; extraction disc: 47mm diameter);
    3, automatic operation, automatic selection of five solvents for SPE column activation, sample loading, elution, cleaning, etc.;
    4, has an extraction channel, is GOODSPE-6000 type 1 channel type, cost-effective;
    5. The solvent pipeline and the sample pipeline are separated and there is an automatic cleaning function to avoid cross contamination;
    6, support for step elution function, can achieve multiple elution;
    7, support dual-column application, suitable for complex sample analysis;
    8, 12-way valve adopts new non-metallic materials, compatible with acid and alkali;
    9, the software can store any method, call out, automatically set;
    10. The instrument has pre-stored 10 system calibration methods to ensure the consistency of the instrument;
    11, the software has sample management and instrument management functions, application is more convenient;
    12, meet the EPA method of water sample test approval standard method, high versatility;
    13. The aqueous and organic wastes are discharged through special discharge pipelines respectively to avoid contamination.
    14, no one-way valve, do not have to worry about a small amount of suspension will plug the pump;
    15. The extraction of liquid samples such as groundwater, surface water, wastewater, fruit juices, etc. (even containing suspended solids) can be performed;
    16. The syringe pump elutes with high repeatability;
    17, the introduction of air to purge the solvent to avoid interference between solvents;
    18. The software can display the working status of the instrument in real time and facilitate the adjustment operation;
    Features:
    1. Gas pressure: Output: 0-30psi (0-1.4bar) Input: Max 100psi (6.9bar);
    2. Syringe pump: Air syringe: 1 10ml syringe LH syringe: 1 10ml syringe;
    3, reversing valve: non-metallic 12-way valve;
    4, pump flow rate: 0-40ml/min per channel;
    5, solid phase extraction column: 1mL extraction column, 3mL extraction column, 6mL extraction column;
    6, solid phase extraction membrane: 47mm SPE extraction membrane disc;
    7, the number of channels: 1;
    8, sample volume: 20mL-20L;
    9, software environment: Windows XP/7 (32 bit);

     
  • Introduction
    One extraction channel is a 1-channel type GOODSPE-6000 automatic solid phase extraction instrument, which is cost-effective; it can process up to 20L of liquid samples for use in drinking water, surface water, groundwater, food, beverage and other sample extracts. Trace organic extraction, designed for large volumes of water analysis. Uses: 1. Environment: insecticides and herbicides, petroleum and grease, polycyclic aromatic hydrocarbons, explosives, PCBs, brominated flame retardants, dioxins, furans organic pollutants, phenyl urea, semi-volatile Organic pollutants, endocrine disruptors; 2. Food: pesticides and herbicides, contaminants in packaged beverages, pesticide residues, natural products, dietary supplements, melamine, antibiotic residues, malachite green, crystal violet , Sulfonamides, quinolones, plasticizers; 3. Pharmaceuticals: analysis of active ingredients in liquids, analysis of extractables in pharmaceutical packaging, vitamins and antibiotics; 4. Other areas:
    Tobacco analysis, flavor and fragrance analysis, cosmetics analysis, azo dye analysis, in vivo metabolism of drugs, narcotic drugs, psychotropic drugs, poison rat poison, life science;
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com