1 Sales GIS-500 Gel Imaging Analysis system,Manufacturer
Position: Home > > Life science instrument and equipment > Imaging system > Gel imaging system > GIS-500 Gel Imaging Analysis system for electrophoresis analysis

GIS-500 Gel Imaging Analysis system for electrophoresis analysis

Product ID:SHCXnjcx021

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGIS-500
    Brand NameHZMO
    Payment TermsT/T, paypal
    Product description:
    GIS-500 Gel Imaging Analysis system is a professional instrument for observing, photographing and analyzing gel bands after electrophoresis. The built-in high-resolution CCD and zoom lens can capture weak electrophoresis bands that are difficult to recognize by the naked eye. Special filter sets are used to effectively filter the background interference noise, while the pollution and UV leakage of ethidium bromide (EBB) can be controlled to the greatest extent. It is easy to display, save, mark or edit the electrophoretic result, arrange the experiment report, print and so on, so as to lighten the burden of the experimenter. Can replace ordinary ultraviolet analyzer or film observation box, is the laboratory indispensable professional instrument.
    Product features:
    1, The appearance design is exquisite, the operation is convenient humanized, the ABS plastic case, the weight is light, the volume is small.
    2, Drawer type operating table, open door on both sides of the door and hidden observation window, easy to take out, observe and cut glue. Built-in gel placement center indicator lamp, easy gel positioning in the center position.
    3. All windows and doors have overlapping and staggered seal structure design, which can enhance the UV transmission effect and space sealing effect of dark chamber, and avoid the harm of ultraviolet ray to human body to the maximum extent.
    4, Double intensity transmission UV wavelength: 312nm, reflectance wavelength: 254365nm, transmission UV area: 25mm × 200mm
    5, Equipped with import low illuminance high resolution digital CCDs, easy to capture weak spectrum band, real-time browsing display, easy to operate. Six times optical manual or automatic zoom lens, easy to zoom gel observation.
    6. The multilayer coated filter set is used to effectively filter the background interference noise; the control functions of zoom, focusing, aperture, ultraviolet lamp and white light can be realized by computer; and the zoom, focusing and aperture can also be realized through the panel. The control function of ultraviolet lamp and white light lamp.
    7. The utility model has the functions of automatic opening of UV light, delayed power loss, leakage protection and so on, which maximizes the protection of users from harm.
    8, With ultra-thin white light board, using the international leading phosphor screen ultraviolet white light conversion technology.
    9. Equipped with special gel imaging analysis software. It has advanced automatic recognition function of swimming lane, which helps to identify, move, adjust and number swimming lane and strip. Export various lab reports to text or Excel format files. Calculation and comparison of nucleic acid, protein molecular weight, optical density, mobility, PH value and percentage content. It has the functions of 1D and 2D analysis Dot blot image processing, colony analysis and clone counting image analysis. For RNA RNAs, proteins, etc. Collection, observation, analysis and preservation of gel images.
    Technical parameters:
    Type V: GIS-500
    Camera head: imported low-illuminance high-resolution digital CCD
    Zoom lens 1: 1: 1.2 / 2 / 3 inch imported 6 times zoom lens
    Effective pixel: 2560 x 1920
    Pixel density: 10 bit
    Pixel size: 5.4 × 5.4 μ m
    Resolution rate: 5 million pixels
    Psionosensitivity: double stranded DNA with less than 20pgEB staining can be detected
    Signal-to-noise ratio: ≥ 56db
    Filter slice: 590nm
    UV transmittance area: 168 × 210mm
    Visible light transmission area: 200 × 250mm
    Transmission area of white phosphor panel: 210 × 260mm
    Transmission UV source wavelength: 312nm
    Reflection UV source wavelength: 254365nm
    Transmission ultraviolet lamp tube power: 302nmMN 8W)
    Reflecting UV lamp tube power: 254nmmt 11W / 365nm / 11W)
    Input power: ac 100% 110 VN 50 / 60 Hz
    Shape size: W.470 × D.405 × H.820mm
    Net weight: 25.0kgs.
     
  • Product description:
    GIS-500 Gel Imaging Analysis system is a professional instrument for observing, photographing and analyzing gel bands after electrophoresis. The built-in high-resolution CCD and zoom lens can capture weak electrophoresis bands that are difficult to recognize by the naked eye. Special filter sets are used to effectively filter the background interference noise, while the pollution and UV leakage of ethidium bromide (EBB) can be controlled to the greatest extent. It is easy to display, save, mark or edit the electrophoretic result, arrange the experiment report, print and so on, so as to lighten the burden of the experimenter. Can replace ordinary ultraviolet analyzer or film observation box, is the laboratory indispensable professional instrument. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com