1 Sales GelView 6000Plus Smart Chemiluminescence Imaging System,Manufacturer
Position: Home > > Life science instrument and equipment > Imaging system > Gel imaging system > GelView 6000Plus Smart Chemiluminescence Imaging System

GelView 6000Plus Smart Chemiluminescence Imaging System

Product ID:SHCXnjcx044

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGelView 6000Plus
    Brand NameGUANGZHOUBOLUTENG
    Payment TermsT/T, paypal
    GelView 6000Plus Smart Chemiluminescence Imaging System
    Introduction
    Used in various chemiluminescence imaging, such as ECL, ECLPlus, SuperSignal, etc.
    For multicolor fluorescence imaging, such as Cy2, Cy3, Cy5, GFP, SYBR Green, SYBR Safe, SYBR Gold, FITC, Fluorescein, Texas Red, fluorescent plates, etc.
    DNA/RNA, protein gel electrophoresis imaging for dyeing various dyes;
    For imaging of various hybrid membranes such as Western, Norther, Southern, Dot/Slot blot;
    Other applications, such as petri dish colony counts, microplates, autoradiographic film analysis, and the like. 
    Features
    1. Imaging for chemiluminescence, multicolor fluorescence, gelation, etc.;
    2. High-resolution CCD: using a 6 megapixel CCD with extremely high resolution and sensitivity;
    3. CCD: deep cooling CCD (up to 55 °C at ambient temperature), can perform long-term luminescence imaging;
    4. Fast cooling speed: 3min can be cooled to -20 °C (absolute temperature);
    5. Comes with a high-performance Windows tablet, full touch screen operation, more intelligent;
    6. Sample platform: double-layer adjustable stage to meet the needs of different imaging fields;
    7. Pixel merging: further increase the sensitivity of chemiluminescence imaging by pixel merging (up to 24×24), capturing weak illuminating signals;
    8. Lens: Using F0.95's large aperture electric fixed-focus lens with auto focus function, it can automatically focus on the sample taken;
    9. Up to five kinds of fluorescent excitation light, which can meet various fluorescence experiments including multi-color fluorescent WB experiments.
    10. Capacitive touch switch integrated in the LOGO to reduce physical buttons on the body;
    11. Electric control stage, infrared inductive power switch, no need to touch, reduce pollution. 
    Technical Parameters
    1. High sensitivity cold CCD camera
    1.1 Gray value: true 16bit
    1.2 pixel value: 2688 × 2200, about 6 million pixels
    1.3 pixel size: 4.54μm × 4.54μm
    1.4 Dynamic Range: > 4.8 OD
    1.5 Sensitivity: as low as pg grade DNA or fg grade protein
    1.6 Refrigeration temperature: 55 ° C at ambient temperature
    1.7 Refrigeration speed: It can be cooled to absolute temperature -20 °C (ambient temperature 25 °C) within 3 minutes, ready to use
    1.8 Dark current: 0.00017e-/pixel/s
    1.9 Binning: 1x1, 2x2, 4x4, 6x6, 8x8, 16x16, 24x24
    1.10 CCD hardware dark current correction technology and pixel point defect correction technology greatly improve the CCD detection signal to noise ratio and obtain the best quality image.
    1.11 QE: 75% @600nm
    1.12 High quality f0.95/25mm wide-angle fixed-focus lens, large aperture, fast exposure
    1.13 four exposure modes are available (Single Exposure, Multiple Exposure, TimeLapse Exposure, Progressive Exposure), exposure time 0.05sec-100min
    2. Black box
     2.1 New design black box with 11.6-inch Windows tablet, resolution: 1920 × 1200, full touch operation
     2.2 Fully automatic access to the sample stage (internal double layer adjustable), infrared inductive switch, no manual touch
     2.3 Power switch integrated in LOGO, capacitive touch switch
     2.4 LOGO with breathing light effect, can automatically switch according to different states of the instrument
     2.5 fully automatic 6-hole filter wheel
    3. Transmitted blue light module
    3.1 detachable design, plug and play
    3.2 Excitation wavelength: 470nm
    3.3 Imaging field of view: 15cm × 18cm
    3.4 590nm patented filter
    4. Multicolor fluorescence module
    4.1 Additional 535nm, 600nm, 700nm, 750nm, 830nm five-emission filter, one-button automatic switching, to meet a variety of fluorescent and near-infrared two-color fluorescence imaging applications
    4.2 Patented wide-angle emission filter technology, the perfect combination of two-phase color mirror and broadband pass filter, effectively remove stray light and improve the sensitivity of fluorescence detection.
    4.3 Five-color LED fluorescent light source (blue 475nm, green 530nm, red 620nm, near-infrared 685nm, infrared 760nm), energy 0-100% adjustable, to meet a variety of fluorescent and near-infrared two-color fluorescence imaging applications
    5. Software
     5.1 BioLight software for image acquisition, BioAnaly software for installation on a personal computer for image analysis
     5.2 The camera software automatically saves the original image data, which cannot be modified and can be exported again.
     5.3 The device automatically saves the usage record and usage status, in line with the GLP specification.
    5.4 The software can perform qualitative and quantitative analysis, annotation, output image and other operations on different samples, such as strips, spots, bacterial clones, chips, cells or living animals.
     5.5 The characteristic operating process aid of the pilot structure makes the software operation easy to use.
     5.6 Three-step lane and strip analysis can quickly calculate the molecular weight and quality of proteins and nucleic acids.
     5.7 Image files are easy to transfer and share on a local or global network.
     5.8 Western Marker and destination strips can be displayed simultaneously on one image
     5.9 Analysis of relative quantification (ratio) and absolute quantification (concentration) of western results
     5.10 Relative and absolute quantitative analysis of the microplate western
     5.11 Protein quantification normalization function, using internal reference protein for correction, reducing errors.

  • Introduction
    Used in various chemiluminescence imaging, such as ECL, ECLPlus, SuperSignal, etc.
    For multicolor fluorescence imaging, such as Cy2, Cy3, Cy5, GFP, SYBR Green, SYBR Safe, SYBR Gold, FITC, Fluorescein, Texas Red, fluorescent plates, etc.
    DNA/RNA, protein gel electrophoresis imaging for dyeing various dyes;
    For imaging of various hybrid membranes such as Western, Norther, Southern, Dot/Slot blot;
    Other applications, such as petri dish colony counts, microplates, autoradiographic film analysis, and the like. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com