1 Sales GC9801 Gas Chromatograph,Manufacturer
Position: Home > > Analytical instruments > Chromatogram > Gas chromatography > GC9801 Gas Chromatograph

GC9801 Gas Chromatograph

Product ID:FSqi042

Price: US$8,000.00 ~ US$15,000.00 PDF Format
Supply Ability:20 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGC9801
    Brand NameGUANGZHOUBIAOJI
    Payment TermsT/T, paypal
    GC9801 Gas Chromatograph
    Introduction
    The GC-9801 gas chromatograph is used to detect organic solvents, to detect solvent residues in packaged prints, and to detect the purity or content of a single solvent.
    Executive standard: QBT10004-2008, YBB00132002 
    Features
    Economical, excellent performance and quality.
    The pressure of the gas path is adjustable, the flow rate is stable, and the nitrogen, hydrogen, air, exhaust, split, and multi-gas system are cleaned.
    The LCD screen displays the temperature in real time.
    The unitary structure is designed for easy installation and maintenance.
    Advanced noise suppression system for quiet work.
    Over-temperature automatic protection, program protection and circuit protection double insurance.
    With data workstations, professional software support, and powerful data analysis capabilities.
    Real-time display of working status and chromatogram curves; curves can be scaled and moved at will.
    Professional test report, can export PDF and other format files.
    Configure the manual button switch, the function is equivalent to the “start acquisition” of the software window, which is convenient for the injection operation.
    Detector and baseline calibration are easy. 
    Technical parameters
    Detector: Hydrogen Flame Detector (FID)
    Detection limit: Mt ≤ 1 × 10-11g / s (hexadecane); baseline drift ≤ 1 × 10-12A / 0.5h; noise ≤ 1 × 10-13A
    Detector: Thermal Conductivity Detector (TCD)
    Sensitivity: S≥2500mv.ml/mg (benzene), baseline drift 60μV/0.5h, noise ≤10μV
    Detector: Electron Capture Detector (ECD)
    Detection limit: M ≤ 2 × 10-13 g / ml (r-666)
    Detector: Flame Photometric Detector (FPD)
    Detection limit: Ms ≤ 5 × 10-11g / s (thiophene), Mp ≤ 1 × 10-11g / s (ethyl - 1605)
    Detector: Nitrogen Phosphorus Detector (NPD)
    Detection limit: Mn: ≤ 1 × 10-13 g / s, Mp ≤ 1 × 10-13g / s (ethyl - 1605)
    Column: OV-1701 capillary column, 50m*0.32mm*0.5um,
    Maximum operating temperature of 280 ° C (optional other columns)
    Inlet: Capillary column inlet (optional packed column inlet)
    Oven size: 240 × 210 × 240mm
    Temperature range: room temperature +10 ° C ~ 400 ° C
    Temperature control accuracy: ≤0.1 °C
    Temperature resolution: 0.1 °C
    Heating rate: 0.1 to 40 ° C / min
    Carrier gas source: Nitrogen N2, purity 99.99%, 0.4MPa, dry
    Hydrogen gas source: purity 99.99%, 0.4MPa, dry
    Air source: 0.4MPa, dry, clean, oil free
    Air source interface: Φ3mm air pipe
    Dimensions: 460 × 440 × 430mm

  • The GC-9801 gas chromatograph is used to detect organic solvents, to detect solvent residues in packaged prints, and to detect the purity or content of a single solvent.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com