Features: High precision, Multi-function, connects the international advanced technology Unique design sampling system, can lower detection limit Can be installed hydrogen flame ionization detector (FID), pool thermal conductivity detector (TCD), electron capture detector (ECD), flame photometric detector (FPD), nitrogen and phosphorus detector (NPD), photoelectric ionization detector (PDHID) of six kinds of detector. Thermal conductivity cell detector (TCD) stable time: ≤10 min Technical parameters: column oven Size :28×30×18cm Temperature range:indoor +5~420℃ Temperature setting :1℃;The programmed heating rate0.1℃ Maximum heating speed:120℃/ min temperature stability:when environment temperature change 1℃,is 0.01℃ temperature programming:7class Can be run column loss compensation (dual channel) injection port: A variety of injection port can match:Packed column injection port, shunt/not bypass capillary filling mouth, cold temperature programmed stigma injection port detect index: flame ionization detector(FID) The maximum control temperature: 400℃ LOD(limit of detection): ≤5×10-12g/s [n-C16] drifting: ≤5×10-13A/30min noise: ≤2×10-13A linear dynamic range : ≥107 thermal conductivity cell detector(TCD) The maximum control temperature: 400℃ sensitivity: ≥10000mv.ml/mg [n-C16] drifting: ≤100uV/30mi noise: ≤20uA linear dynamic range: ≥105 Electron capture detector(ECD) The maximum control temperature: 350℃ LOD(limit of detection): ≤6×10-15 g/ml (γ-666) drifting: ≤50uV/30min noise: ≤20uV linear dynamic range: ≥104 Flame photometric detector(FPD) The maximum control temperature: 400℃ LOD(limit of detection): ≤2×10-13g/s(P) ≤5×10-11g/s(S) drifting: ≤4×10-11A/30min noise: ≤2×10-12A linear dynamic range: ≥103(P) ≥102(S) Nitrogen and phosphorus detector(NPD) The maximum control temperature: 400℃ LOD(limit of detection): ≤5×10-13g/s(P) ≤1×10-12g/s(N) drifting: ≤25×10-12A/30min noise: ≤4×10-13A linear dynamic range: ≥103(P) Photoelectric ionization detector(PDHID) LOD(limit of detection): ≤5ppb Application Petroleum, chemical, food, pharmaceutical, environmental protection, for disease control and prevention, safety, water, electricity, metallurgy, scientific research institutes, quality inspection department.
Features: High precision, Multi-function, connects the international advanced technology Unique design sampling system, can lower detection limit Can be installed hydrogen flame ionization detector (FID), pool thermal conductivity detector (TCD), electron capture detector (ECD), flame photometric detector (FPD), nitrogen and phosphorus detector (NPD), photoelectric ionization detector (PDHID) of six kinds of detector. Thermal conductivity cell detector (TCD) stable time: ≤10 min