Position: Home > > Analytical instruments > Chromatogram > Gas chromatography > GC126 Gas chromatograph for Oil field analysis

GC126 Gas chromatograph for Oil field analysis

Product ID:FSqi009

Price: Please inquire PDF Format
Supply Ability:20sets/mon
Port:shenzhen
share:
  • Product Introduction
  • Consulting
  • Model NumberGC126
    Brand NameYIMA
    Payment TermsT/T, paypal
    Brief introduction
          The newly designed GC126 gas chromatograph , using the international advanced control technology . High temperature accuracy ( better than ± 0.1 ) superior reliability and robustness. Control and use the keyboard to set the various parameters , the machine has a self- diagnosis , power protection , file storage and call , extreme temperature setting and other functions. 3.8 " large screen can accurately display the brightest temperature setpoint, actual value and real-time curve , each detector parameters , the signal value and its real-time curve . Control area has six independent : the oven , injector , detector, aids . The product can achieve nine bands temperature program , after the oven has automatic cooling function that is open to achieve rapid heating and rapid cooling . Instrument base with a double and a single type of high sensitivity hydrogen flame ionization detector (FID), one of the following optional detectors, gas sampling valve , reformer and other accessories can also install two detectors and detection high sensitivity ( e.g. FID test results for : DFID≤4 × 10-12g / s), the settling time is short, easy cleaning and nozzle mounting
     Features :
         Embedded 32-bit processor and multi- CPU systems development, IT interface-related technology, automatic temperature parameter settings, select the detector , the detector operating parameters and data of the auto-zero function , sensitivity and polarity of digital settings.
    Full Chinese menu interface , and can display multiple sets of parameters , the operation is very simple and convenient.
    Computer anti-control function , you can operate the instrument all the features inside the computer ( via USB interface ) No external workstation and provides an analog output interface.

    Technical parameters
         Column temperature box:
    Scope: 1. The temperature at room temperature 5 ℃ to 400 
    2. The control precision, plus or minus 0.1 
    3. The temperature programmed: 9 order
    4. The maximum heating rate: 60 ℃ / min
    5. Dual channel chromatographic column loss compensation
    Sampler:
    1. The sample can load up to three (two packed column sample, 1 capillary column sample) or 2 sample capillary column.
    2. The sampler unit: independent shunt/no shunt sampler and packed column injector system
    Detector:
    1. The maximum load three detector
    2. The hydrogen flame ion detector (FID) :
    Temperature range for room temperature 7 ℃ ~ 400 ; Detection limit 4 x 10 to 12 g/s, or less samples: C16
    3. The micro thermal conductivity detector (mu - TCD) :
    The electron capture detector (ECD):
    Temperature range from room temperature plus 7 
    ℃ ~ 350 ; sources : 63Ni10 ~ 12mci; minimum detectable amount : 5 × 10-14g / ml sample : r666
    5. The flame photometric detector (FPD):
    Temperature range from room temperature plus 7 
    ℃ ~ 400 ; detection limit ≤3 × 10-12g / s (P) ≤4 × 10-11g / s (S)
    6. nitrogen and phosphorus detector (NPD):
    Temperature range from room temperature plus 7 
    ℃ ~ 400 ; detection limit ≤5 × 10-12g / s (N), ≤5 × 10-13g / s (P)
     

  • Brief introduction
          The newly designed GC126 gas chromatograph , using the international advanced control technology . High temperature accuracy ( better than ± 0.1 ℃) superior reliability and robustness. Control and use the keyboard to set the various parameters , the machine has a self- diagnosis , power protection , file storage and call , extreme temperature setting and other functions. 3.8 " large screen can accurately display the brightest temperature setpoint, actual value and real-time curve , each detector parameters , the signal value and its real-time curve . Control area has six independent : the oven , injector , detector, aids . The product can achieve nine bands temperature program , after the oven has automatic cooling function that is open to achieve rapid heating and rapid cooling . Instrument base with a double and a single type of high sensitivity hydrogen flame ionization detector (FID), one of the following optional detectors, gas sampling valve , reformer and other accessories can also install two detectors and detection high sensitivity ( e.g. FID test results for : DFID≤4 × 10-12g / s), the settling time is short, easy cleaning and nozzle mounting

Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com