Position: Home > > Analytical instruments > Chromatogram > Gas chromatography > GC112A gas chromatograph With Automatic fault identification

GC112A gas chromatograph With Automatic fault identification

Product ID:FSqi018

Price: Please inquire PDF Format
Supply Ability:20sets/mon
Port:Shenzhen
share:
  • Product Introduction
  • Consulting
  • Model NumberGC112A
    Brand NameYIMA
    Payment TermsT/T, paypal

    Features and performance:
    1. High temperature accuracy (better than ± 0.05 ℃) superior reliability and robustness.
    2. The product can achieve five stage temperature programming , after the oven has automatic cooling function that is open to achieve rapid cooling .
    3. Can be easily installed packed and capillary column ( 0.53 large diameter column or small caliber column ) , and the annex with a full split injection capillary fittings and makeup joints (no extra charge ) 
    4.The instrument can be packed column analysis or analysis of capillary columns , can achieve a variety of injection methods .
    5. The instrument has a double gas road , twin injectors , dual packed column system structure, can effectively inhibit the baseline fluctuation and drift in real time , suitable for temperature programming analysis .

    6. The instrument has an automatic opening and automatic shutdown temperature control systems, data permanently stored , file storage and call , over-temperature protection , and other advanced features.
    7. Large capacity oven (300mm × 280mm × 270mm) for easy installation and dual capillary column packed column ; Built-in heating wire structure more conducive to quartz capillary column analysis .
    8. Using CAD design technology, mechanical parts and high reliable structure and appearance, very humane.

    Technical Specifications:
    1.Temperature control:
    Temperature range : The temperature 7 ℃ ~ 400 ℃ ( increment 1 ℃)
    Temperature object : oven , detector, thermal conductivity , injector, aids ( spare )
    Drive up the order : five bands
    Cheng liter rate : 0.1 ℃ ~ 40 ℃ / min ( increments of 0.1 ℃)
    Holding time : 0 ~ 655min ( incremental 1min)

    2.flame ionization detector (FID):
    Detection limit : DFID≤5 × 10-11 g / s ( Sample : C16)
    Best test results : DFID≤1 × 10-11 g / s
    Baseline Noise : ≤5 × 10-14A
    Baseline Drift : ≤6 × 10-13A / h
    Linear range : ≥106

    3.thermal conductivity detector (TCD)
    Sensitivity : ≥2000mV. ml / mg
    Baseline Noise : ≤20μV
    Baseline drift : ≤30μV
    Linear range : ≥104

  • Features and performance:
    1. High temperature accuracy (better than ± 0.05 ℃) superior reliability and robustness.
    2. The product can achieve five stage temperature programming , after the oven has automatic cooling function that is open to achieve rapid cooling .
    3. Can be easily installed packed and capillary column ( 0.53 large diameter column or small caliber column ) , and the annex with a full split injection capillary fittings and makeup joints (no extra charge ) 
    4.The instrument can be packed column analysis or analysis of capillary columns , can achieve a variety of injection methods .
    5. The instrument has a double gas road , twin injectors , dual packed column system structure, can effectively inhibit the baseline fluctuation and drift in real time , suitable for temperature programming analysis .

    6. The instrument has an automatic opening and automatic shutdown temperature control systems, data permanently stored , file storage and call , over-temperature protection , and other advanced features.
    7. Large capacity oven (300mm × 280mm × 270mm) for easy installation and dual capillary column packed column ; Built-in heating wire structure more conducive to quartz capillary column analysis .
    8. Using CAD design technology, mechanical parts and high reliable structure and appearance, very humane.

Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com