1
Features and performance:
1. High temperature accuracy (better than ± 0.05 ℃) superior reliability and robustness.
2. The product can achieve five stage temperature programming , after the oven has automatic cooling function that is open to achieve rapid cooling .
3. Can be easily installed packed and capillary column ( 0.53 large diameter column or small caliber column ) , and the annex with a full split injection capillary fittings and makeup joints (no extra charge )
4.The instrument can be packed column analysis or analysis of capillary columns , can achieve a variety of injection methods .
5. The instrument has a double gas road , twin injectors , dual packed column system structure, can effectively inhibit the baseline fluctuation and drift in real time , suitable for temperature programming analysis .
6. The instrument has an automatic opening and automatic shutdown temperature control systems, data permanently stored , file storage and call , over-temperature protection , and other advanced features.
7. Large capacity oven (300mm × 280mm × 270mm) for easy installation and dual capillary column packed column ; Built-in heating wire structure more conducive to quartz capillary column analysis .
8. Using CAD design technology, mechanical parts and high reliable structure and appearance, very humane.
Technical Specifications:
1.Temperature control:
Temperature range : The temperature 7 ℃ ~ 400 ℃ ( increment 1 ℃)
Temperature object : oven , detector, thermal conductivity , injector, aids ( spare )
Drive up the order : five bands
Cheng liter rate : 0.1 ℃ ~ 40 ℃ / min ( increments of 0.1 ℃)
Holding time : 0 ~ 655min ( incremental 1min)
2.flame ionization detector (FID):
Detection limit : DFID≤5 × 10-11 g / s ( Sample : C16)
Best test results : DFID≤1 × 10-11 g / s
Baseline Noise : ≤5 × 10-14A
Baseline Drift : ≤6 × 10-13A / h
Linear range : ≥106
3.thermal conductivity detector (TCD)
Sensitivity : ≥2000mV. ml / mg
Baseline Noise : ≤20μV
Baseline drift : ≤30μV
Linear range : ≥104
Features and performance:
1. High temperature accuracy (better than ± 0.05 ℃) superior reliability and robustness.
2. The product can achieve five stage temperature programming , after the oven has automatic cooling function that is open to achieve rapid cooling .
3. Can be easily installed packed and capillary column ( 0.53 large diameter column or small caliber column ) , and the annex with a full split injection capillary fittings and makeup joints (no extra charge )
4.The instrument can be packed column analysis or analysis of capillary columns , can achieve a variety of injection methods .
5. The instrument has a double gas road , twin injectors , dual packed column system structure, can effectively inhibit the baseline fluctuation and drift in real time , suitable for temperature programming analysis .
6. The instrument has an automatic opening and automatic shutdown temperature control systems, data permanently stored , file storage and call , over-temperature protection , and other advanced features.
7. Large capacity oven (300mm × 280mm × 270mm) for easy installation and dual capillary column packed column ; Built-in heating wire structure more conducive to quartz capillary column analysis .
8. Using CAD design technology, mechanical parts and high reliable structure and appearance, very humane.